Electrical connection, Fitting the extractor hood – Siemens LU14122FF Manuel d'utilisation

Page 26

Advertising
background image

26

Electrical connection

3. Connect the brown (Live) wire to the

terminal marked ‘L’, or coloured red.

The extractor hood may be connected to
a correctly installed earthed socket only.
Attach the earthed socket near the
extractor hood in an accessible position.
❑ The earthed socket should be

connected via its own power circuit.

If appliances do not feature the OFF

delay function, the indicator may start flas-
hing when the extractor hood has been
switched off for several hours via a separa-
te switch, even though the grease filters are
not yet saturated.
(See instructions for use, section on filter
and maintenance).

Electrical specifications:

These can be found on the rating plate
inside the appliance following removal of
the filter frames.

Before carrying out repairs, always

isolate the appliance.
Length of the connection cable: 1.30 m.
If permanent connection is required:
The extractor hood may only be connected
by an electrician registered with the local
electricity board.
A disconnecting device must be provided
on the installation side. Switches with a
contact opening of more than 3 mm and
all-pole disconnection are regarded as
disconnecting devices. These include LS
switches and contactors.

This extractor hood complies with EU
regulations on interference suppression.

Fitting the extractor hood

60 cm wide extractor hood:
With 3 screws.

100

21

102 57

598

140

127

536

180

90 cm wide extractor hood:
With 5 screws.

140

898

536

21

102

180

127

100

57

836

1. Mark mounting boreholes.

Dimensions can be found in or use
template.

2. Drill 8 mm dia. holes and insert wall

plugs flush with the wall.

3. Screw in the upper screws (on left and

right) until there is a gap of approx.
7 mm between the screw head and the
wall.

Fitting the extractor hood

To the wall

50 cm wide extractor hood:
With 3 screws.

100

21

102 57

498

140

127

436

180

4. Remove the filter grille

(see Instructions for use)

5. Attach the extractor hood.

6. Tighten the lower screw (with washer)

inside the extractor hood.

Advertising