Before installation, Electrical connection – Siemens LU14122FF Manuel d'utilisation

Page 25

Advertising
background image

25

Before installation

To prevent damage to the fan, hold the

tool vertically.
❑ Remove the broken off metal part

(possibly a noisy and disruptive
procedure).

❑ If the extractor hood has 2 motors, the

opening on the plastic part must be
made at the rear; cut through the 3 ribs
and remove the cut-off part.

Exhaust air towards the rear:
Pipe diameter: 100 mm
❑ Break off cover on the rear panel of the

extractor hood; strike the retaining
points with a tool.

❑ Cut off the outer part of the exhaust-air

connection.

❑ Insert the inner part and turn as far as

possible.

Circulating-air mode

❑ With activated carbon filter if exhaust-air

mode is not possible.

❑ The air purified by an additional

activated carbon filter is conveyed back
into the room.

❑ For insertion of the activated carbon

filter see Instructions for use.

❑ If the extractor hood is switched from

exhaust-air mode to circulating-air
mode, the exhaust-air opening must be
sealed to prevent a hazardous situation
(see optional accessories in the
Instructions for use).

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED

IMPORTANT: Fitting a Different Plug:

The wires in the power cord are colour-
coded as follows:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of these
wires may not correspond with the identify-
ing marks on the plug terminals.

Proceed as follows:

1. Connect the green and yellow (Earth)

wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or
coloured green or green and yellow.

2. Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or
coloured black.