Mounting

Wiring

• The sensor module is intended to be

installed within a luminaire. Its dome

antenna must face the desired area

of detection (the fi xture’s area of

illumination).

• The dome antenna must have an

unobstructed view of the detection

area. The high frequency signal is

not obstructed by materials such as

polycarbonate, plastic or glass. Metal

will obstruct the high frequency signal.

Mounting

Mounting guidelines

4

• Mounting screw holes are 3.8 inches

(97 mm) apart.

• Suitable for wall and ceiling

applications.

• For indoor use only

• For optimal coverage, the dome

antenna must project beyond the

lamps and should not be blocked by

any metal.

• Pay attention to luminaire materials

(interference, refl ections, attenuation).

5

There are three terminals for streamlined

wiring.

Use only solid (16-20) AWG CU wire.

Strip insulation (9-10mm/0.37 inch)

Operation

The HFLUM2-120 operates by turning

lights on automatically when occupancy

is detected and off when the space is left

vacant and the time delay has elapsed.

Light level function

The light level feature keeps lighting

off during daylight hours, regardless of

occupancy.

Surge protection

Every sensor contains built in surge

protection. This feature will reset the

unit automatically after: power surges,

power outages, and power shortages.

Surge protection protects the sensor if it

is miswired as well. If miswired, shut off

power, correct the wiring, and the sensor

will then operate correctly.

107 mm

4.2”

97 mm

3.8”

44.5 mm

1.75”

42 mm

1.65”

www.steinel.net (800) 852-4343

www.steinel.net (800) 852-4343

LOAD

NEUTRAL