3 setting up – AKG Acoustics PERCEPTION 820 Manuel d'utilisation

Page 7

Advertising
background image

7

PERCEPTION 820 TUBE

3 Setting Up

3.1 Important Note

3.2 Connecting
the Microphone

Fig. 3: Connecting the micro-
phone to the Remote Control
Unit and mixer.

Refer to fig. 3.

3.3 Connecting
the Remote Control Unit
to Power
Refer to fig. 2 on page 5.

Table 1: Power voltage vs. se-
lector setting and power cord

Important!

3.4 Powering Up

Note:

• To avoid damage or electric shock, mount the microphone on a suitable stand

and make all audio connections before connecting the Remote Control Unit to
power.

1. Use the supplied audio/control cable (A) to connect the microphone output to the INPUT

connector(B) on the Remote Control Unit rear panel.

2. Use a standard balanced XLR cable (C) (optional) to connect the OUTPUT connector (D)

on the Remote Control Unit rear panel to the desired microphone input on your mixer.

1. Prior to connecting the Remote Control Unit to power, check what power voltage is avail-

able where you are going to use the microphone.

2. Set the power voltage selector (G) on the rear panel to the correct position as shown in

Table 1 below.

3. Referring to Table 1 above, use the correct power cord to connect the Remote Control

Unit to a grounded power outlet.

When on tour, you may encounter power outlets that do not match the power plug on
any of the supplied power cords.

• Purchase a suitable power cord locally that complies with IEC and local safety

standards and has a power plug with a chassis ground pin.

• To avoid damage or electric shock, connect the Remote Control Unit to a grounded

power outlet only.

• If in doubt about the power connection, consult a local electrician.

• Set the power switch on the Remote Control Unit rear panel to “I”.

After about ten seconds, the heating voltage will have reached the specified level and
the front panel POWER LED will be lit. About twenty seconds later, the microphone will
be ready to operate.

• You may not get the full splendor of the tube sound before the electrodes have reached

the required operating temperature. Therefore, we recommend powering up at least

!

A

B

D

Power voltage

Selector setting

Power cord

210 to 240 VAC, 50/60 Hz

210-240V

UK or European type

110 to 120 VAC, 50/60 Hz

110-120V

US type

!

C

Perception_820_Manual_final4_C030818 02/05/2009 11:26 Seite 7 (Schwarz/Black Auszug)