6 troubleshooting – AKG Acoustics PERCEPTION 820 Manuel d'utilisation

Page 17

Advertising
background image

17

PERCEPTION 820 TUBE

6 Troubleshooting

6.2 Solving Problems

Problem

Possible Cause

Remedy

No sound.

1. Power to mixer and/or recording

device is off.

2. Channel or master fader on mixer

or recording device is at zero.

3. Microphone is not connected to

mixer or recording device.

4. Cable connectors are seated

loosely.

5. Audio cable or audio/control cable

is defective.

6. No supply voltage.

7. Vacuum tube inside microphone is

defective.

8. Fuse blown.

1. Switch power to mixer and/or

recording device on.

2. Set channel or master fader on

mixer or recording device to de-
sired level.

3. Connect microphone to mixer or

recording device.

4. Check cable connectors for secure

seat.

5. Check cables and replace damaged

cable(s).

6. Check POWER LED. Switch power

to Remote Control Unit on.
Check audio/control cable and re-
place if necessary.

7. Contact your nearest AKG Service

Center.

8. Check POWER LED. Refer to sec-

tion 6.1 above or contact your
nearest AKG Service Center.

Distortion.

1. Channel gain control on mixer set

too high.

2. Microphone too close to sound

source.

3. Microphone sensitivity set too high.

1. Turn gain control down CCW.

2. Move microphone further away

from sound source.

3. Switch preattenuation pad in.

Crackling noises or low output.

• Partial short circuits due to exces-

sive humidity.

• Place microphone in warm, dry

room and allow to dry.

Perception_820_Manual_final4_C030818 02/05/2009 11:26 Seite 17 (Schwarz/Black Auszug)

Advertising