FLUE SIZE
6”
Certification File #
367-S-03b-5
FOR BECKETT BURNER (MLPGFH315-400)
MAXIMUM INLET PRESSURES: LP—12.0 IN. WC. NG—12.0 IN. WC.
MINIMUM INLET PRESSURES: LP—8.0 IN. WC. NG--8.0 IN. WC.
BLAZE 400 G
SPECIFICATIONS
BLAZE 400G-
RIELLO (NG/LP)
Burner Make & Model
Riello G400
Voltage
120 Volts
Input (BTU/h)
399,000
Heater Air and Full Load
Amps (CFM/Amps)
3,500/11.5
MOTOR HP
1
Ductability
24ft on outlet and
12ft on inlet
Outlet Duct Size
(2) X 12”
Inlet Duct Size
(2) X 12”
NG Set up (All heaters
come factory set for
Propane use)
Easy switch over
Blue handle Ball
Valve on Gas
manifold.
Closed position:
Propane
Open position:
Natural Gas
Main Orifice
Main Orifice: 2.2
Washer: C6
Manifold pressure “W.C.
3.5