through the case.

5. Erect the side walls and cut the opening or orient the

pre-fabricated opening. Frame with 2” x 2” lumber (or

equivalent).
6. Pull the unit outward through the opening and bend all

four flanges outward 90 degrees along the lanced lines.

Installation in standard 6 gallon water heater opening with

Standard Door Kit

Installation in standard 10 gallon water heater opening with

Large Door Adapter Kit

7. To prevent water leaks, caulk thoroughly around the

backside of the flanges over the lanced bend slots. Caulk

the perimeter of the opening (or substitute 1” x 3/8” Butyl

Tape).
8. Push the unit to the wall against the caulking and secure

the corner brackets behind the unit flanges but snug to

the corner of the enclosure. Complete the installation

by inserting #8 screws in all the flange holes, ensuring

that the casing is installed completely square allowing for

a good door fit.

an “air tight” seal must be the final result.

gEnEraL inStaLLation

The following instruction describes the most common type
of installation for the water heater. However, there are other
approved methods such as baggage compartment and flush
mounting. Consult your Field Auditor, Account Manager, or the
Atwood Service Department if you have additional questions.
These steps assume the proper location has been determined
and is being installed at the OEM prior to erecting the walls.
noTe: Parts bagged and included with the unit in the box are
the corner filler brackets and push on water line connectors.

1. Locate the water heater on the floor of the coach at pre-

determined location. The unit must be permanently

supported at the same level as the bottom of the sidewall

cutout (by the floor or a raised floor).

2. To install the unit on carpeting, assure the addition

of metal or wood under the unit is added and extends

a minimum of three inches beyond the width and

depth of the appliance enclosure. Minimum clearance

requirement is zero (except front door for proper operation

and service).

3. If risk of future connection leakage and damage of

adjacent area is of concern, install a drain pan under the

unit with drainage to outside of vehicle.

4. Connect plumbing to water lines with fittings provided

taking care to make correct “COLD” and “HOT”

orientation. Connect 3/8” FM flared LP gas line to 3/8” M

flared gas fitting.

a. Allow flexibility in water and gas lines so the unit

can be pulled through the sidewall opening at least

one inch past the skin, allowing for sealing step.

b. Assure the water and gas line grommets continue

to be intact and properly inserted in the case holes,

with no gaps or openings where the line passes

m

caution

PrODUCT DAMAGe

Gas connection must be made using TWO (2) wrenches

to avoid twisting and damaging line.

Damage voids the Warranty!

Cold In

Hot Out

Gas Connection

Corner Brackets