Installation of EL Reflector :

1.For 2-lamp configurations, connect EL test switch to mating plug included with rough-in section. Attach socket housing to top of reflector
by aligning/inserting corner of socket housing into raised tabs on top of reflector. NOTE - make sure that EL test switch wire and plug is
placed completely inside socket housing
. Align screw on socket housing with keyhole slot in top of refelctor and push socket housing
forward (see Figure 1). Secure socket housing and reflector together by tightening the screw.

2. Insert reflector through the ceiling opening making sure to tilt reflector (see Figure 2). Align reflector attachment screw (see Figure 3) with
keyhole slot in reflector assembly. Tighten the attachment screw until the reflector is flush against the ceiling.

3. For 1-lamp configurations, make emergency ballast assembly and test switch/pilot light connection by plugging the two connectors
together (see Figure 5).

4. Push wires and connectors into opening of test switch/pilot light box fastened to reflector. Install flex connector into box making sure
that flex is oriented in direction of arrow (see Figure 6).

Symptom

Possible Cause

Corrective Action

LAMP FAILS TO
LIGHT

•Circuit feeding the fixture not energized.
•Wiring error in circuit or module
connection.
•Faulty lamp.

•Line or ballast output.
•Faulty ballast.
•Ambient temperature too low.

•Check circuit breaker or fuse to ensure that circuit is energized.
•Examine fixture splice box to ensure that connections are correct.

•Remove the faulty lamp and substitute another lamp. Preferably
one that is known to light. If lamp lights, replace the original with a
new one.
•Check line voltage at fixture. Check open circuit voltage.
•Check circuit continuity.
•Check ballast rating against existing environmental conditions.

LAMP GOES OUT
AFTER LIGHTING

•Faulty lamp

•Occasionally a lamp will exhibit this symptom rather than simply
failing to light. Substitute a new lamp.

LAMP CYCLES ON
AND OFF

•Insulation too close to fixture.
•Lamp wattage too high.
•Ballast output voltage low.

•Remove installation from around module (at least 3”).
•Install lamp wattage specified in housing.
•Check line voltage at the fixture. Check open circuit voltage.

TROUBLESHOOTING CHART
Check for any visible damage to the lamp or frame-in module. If they seem in good condition, locate the problem in the
following list of possible causes and corrective actions.