Mesh Filter Clean Indicator (always enabled)
- After 30 hours of fan usage the Graphic and words “

clean mesh filter

” will illuminate indicating it is time to clean

the mesh filters. Graphic and words will remain illuminated until reset.
- To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “

clean mesh

filter

” will turn off and the 30 hour timer will reset.

Charcoal Filter Replace Indicator (disabled by default, must be enabled if recirculating hood)
- To enable Charcoal Filter Replacement Function:

- With hood off, hold Button and Button simultaneously for three seconds. The Graphic will illuminate for

three seconds indicating the Charcoal Filter Replacement Function is enabled.

- To disable Charcoal Filter Replacement Function:

- With hood off, hold Button and Button simultaneously for three seconds. The Graphic will be

illuminated then turn off indicating the Charcoal Filter Replacement Function is disabled.

- After 120 hours of fan usage the Graphic and words “

replace charcoal filter

” will illuminate indicating it is time to

replace the charcoal filter. Graphic and words will remain illuminated until reset.
- To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “

replace

charcoal filter

” will turn off and the 120 hour timer will reset.

Clean Air Indicator
- Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.

- To enable Clean Air Function:

- With hood off, hold the Button and Button simultaneously for three seconds. The Graphic and

words “

clean air

” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan

will turn off and the 4 hour timer will begin.

- Graphic will remain on when Clean Air Function is enabled, even if fan is not on.

- To disable Clean Air Function:

- With hood off, hold the Button and Button simultaneously for three seconds until Graphic

turns off.

- When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10
minutes the fan will turn off and the 4 hour timer will reset.
- If the user changes the fan speed while the Clean Air Function is in use, the words “

clean air

” will turn off but the Graphic

will remain illuminated. If the user presses the Button at any time the 4 hour clean air timer will reset.