Tighten strain relief screw, Wire connection: power supply cord, Tighten strain relief screws – Whirlpool Cabrio W10164159B Manuel d'utilisation

Page 11: Wire connection: direct wire

Advertising
background image

11

3. Connect ground wire (green or bare) of direct wire cable to

external ground conductor screw. Tighten screw.

A

C

D

F

B

E

A. External ground conductor screw
B. Neutral ground wire

C. Ground wire (green or bare) of power supply cord
D. ¾" (19 mm) UL listed strain relief

E. Center, silver-colored terminal block screw

F. Neutral wire (white or center wire)

4. Place the hooked ends of the other direct wire cable wires under

the outer terminal block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.

5. Tighten strain relief screw.

6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

A

B

D

C

E

F

G

A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug

C. Neutral prong
D. Spade terminals with upturned ends

E.

3

/

4

" (19 mm) UL listed strain relief

F. Ring terminals

G. Neutral wire (white or center wire)

1. Loosen or remove center, silver-colored terminal block screw.

2. Connect neutral wire (white or center wire) of power supply cord

to the center, silver-colored terminal screw of the terminal block.
Tighten screw.

A

B

C

D

E

A. External ground conductor screw
B. Neutral ground wire

C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

3. Connect the other wires to outer terminal block screws. Tighten

screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Direct Wire

Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can
be moved if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm). If using 3-wire cable with ground wire,
cut bare wire even with outer covering. Shape ends of wires into a
hook shape.

1"

(25 mm)

3½"

(89 mm)