Four-wire connection...

Four-wire power supply cord must have
four, No.-10 copper wires and match a
four-wire receptacle of NEMA Type
14-30R. The fourth wire (ground
conductor) must be identified with a
green cover and the neutral
conductor by a white cover.

NEUTRAL

NEUTRAL (white)

3/4" U.L.-listed
strain relief

ground prong

ground wire
(green)

ring terminals

spade
terminals with
upturned ends

4.

Remove center terminal block screw.

4.

Remove center terminal block

screw.

6.

Connect ground wire (green) of

power supply cord to external
ground conductor screw. Tighten
screw.

7.

Place the hooked end of the

neutral wire (white or center) of
power supply cable under the center
screw of terminal block (hook facing
right). Squeeze hook end together.
Tighten screw.

8.

Place the hooked ends of the

other power supply cable wires
under the outer terminal block screws
(hook facing right). Squeeze hooked
ends together. Tighten screws.

7.

Connect neutral wire (white or

center) of power supply cord under
center screw of the terminal block.
Tighten screw.

8.

Connect the other wires to outer

terminal block screws. Tighten screws.

6.

Connect the ground wire (bare)

of the power supply cable to the
external ground conductor screw.
Tighten screw.

9.

Tighten strain relief screws.

10.

Insert tab of terminal block cover

into slot of dryer rear panel. Secure
cover with hold-down screw.

9.

Tighten strain relief screws.

10.

Insert tab of terminal block cover

into slot of the dryer rear panel. Secure
cover with hold-down screw.

5.

Remove appliance ground wire

(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.

5.

Remove appliance ground wire

(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.

POWER SUPPLY CORD

DIRECT WIRE

Preparing the wire:

3/4" U.L.-
listed strain
relief

to
disconnect
box

NEUTRAL wire
(white or center)

10-gauge, 3-wire
with ground wire
(Romex)

5" (12.7 cm)

3-1/2" (8.9 cm)

1" (2.5 cm)
of wires
stripped of
insulation

bare ground

wire

Strip 5" (12.7 cm) of outer
covering from end of
cable. Leave bare ground
wire at 5 inches (12.7 cm).
Cut 1-1/2" (3.8 cm) from
3 remaining wires. Strip
insulation back 1 inch
(2.5 cm).

Shape
ends
of
wires
into a
hook.

Four-wire receptacle (required for mobile homes)