Three-wire connection, Power supply cord, Direct wire – Whirlpool 8527795 Manuel d'utilisation

Page 10: Where local codes permit, Preparing the wire

Advertising
background image

Three-wire connection...

Three-wire power supply cord must have
three, No.-10 copper wires and match a
three-wire receptacle of NEMA Type
10-30R.

4.

Loosen or remove center

terminal block screw.

6.

Connect the other wires to

outer terminal block screws.
Tighten screws.

7.

Tighten strain relief screws.

8.

Insert tab of terminal block

cover into slot of dryer rear panel.
Secure cover with hold-down
screw.

5.

Connect the neutral wire (white

or center) of power supply cord to
the center, silver-colored terminal
screw of the terminal block.
Tighten screw.

POWER SUPPLY CORD

Three-wire receptacle

NEUTRAL

NEUTRAL

(white or center)

3/4" U.L.-listed

strain relief

This blade connected
to this conductor.

ring
terminals

spade
terminals with
upturned ends

Where local codes permit

connecting cabinet-ground conductor to neutral wire:

Where local codes permit

connecting cabinet-ground conductor to neutral wire:

4.

Loosen or remove center

terminal block screw.

7.

Tighten strain relief screws.

8.

Insert tab of terminal block cover

into slot of dryer rear panel. Secure
cover with hold-down screw.

6.

Place the hooked ends of the

other power supply cable wires
under the outer terminal block
screws (hook facing right). Squeeze
hooked ends together. Tighten
screws.

5.

Place the hooked end of the

neutral wire (white or center) of
power supply cable under the center
screw of the terminal block (hook
facing right). Squeeze hooked end
together. Tighten screw.

DIRECT WIRE

Preparing the wire:

Strip 3-1/2" (8.9 cm) of
outer covering from
end of cable. Strip
insulation back
1" (2.5 cm). If using
3-wire cable with
ground wire, cut bare
wire even with outer
covering.

Shape
ends of
wires into
a hook.

10-gauge, 3-wire or,
10-gauge, 3-wire with
ground wire (Romex)

3/4" (1.9 cm)
U.L.-listed strain
relief

Three-wire with ground wire:
Bare wire cut short. Wire is not
used. Dryer is grounded through
direct wire cable.

to
disconnect
box

NEUTRAL wire
(white or center)

1" (2.5 cm)
of wires
stripped of
insulation

3-1/2" (8.9 cm)

Page 10