Installation

Important: This thermostat must be installed according to all national
and local electrical codes. The installation must be performed by quali-
fied personnel.

Locating the floor temperature sensor

The floor temperature sensor is installed under the floor surface. See the
QuickNet System Installation Manual (H57704), Section 6, for more
details.

If required, the sensor cable can be extended to about 300 ft (91 m).

Wiring the thermostat

WARNING: TURN OFF THE POWER TO THE CIRCUIT

AT THE MAIN POWER PANEL TO AVOID ELECTRIC SHOCK.

WARNING: SHOCK HAZARD. TO PREVENT SHOCK, THE QUICKNET

FLOOR WARMING MAT MUST BE CONNECTED TO GROUND.

1. Connect power to the thermostat’s line terminals marked “L1 (L)”

and “L2 (N)”.

2. Connect the floor warming cold lead to the load terminals marked

“Load 16A Max”.

3. Connect the floor warming cold lead braid (ground) to the supply

ground in the electrical junction box.

4. Connect the floor temperature

sensor to the screw-less
terminals marked “Sensor”.
Push on the terminal spring
with a screwdriver and
insert the wires.

Mounting the thermostat in the electrical box

1. Use a screwdriver to remove the cover.

2. Mount the thermostat in the wall socket and re-attached the cover.

Thermostat Controls and Display Symbols

The following figure shows the thermostat controls:

The following figure shows the symbols that appear in the display
window while you are programming:

Reset

GFCI

Test

R

Reset button

Red light indicating

ground-fault

Test button

Pin button for

adjusting clock

Adjustment up

OK - accept

Digital
display

Adjustment down

Reset button for
factory settings

L1 (L)

L2 (N)

240/(120)VAC

16A

Max.

QuickStat

®

GFCI Class A

LINE

LOAD

SENSOR

1/4" (6 mm)

Strip length

Line (black)

Line 2 (red) or Neutral (white)

Cold lead

Cold lead

QuickStat Installation & Operation Manual

2

Supply
ground

Cold lead
ground

Wire nut

Clock function

Manual mode

Time and

temperature

Day number

4-event symbol:

Wake

Night

Out

Home

% switch-on time

Heating on