Installation & Servicing Instructions Rinnai E-Series

72

15

Blocks and Errors

15.1 Error indication (short reference)

A detected error is indicated on the display by means of blocking or error messages. A
distinction should be made between these two messages due to the fact that blocking
can be of a temporary nature, however, error messages are fi xed lockings. The control
will try its utmost to prevent locking and will temporarily switch off the unit by blocking
it. Hereunder is a list of some messages.

Blocks

with a number in the last 2 positions.

Block

01:

External safety contact cut off

Block

60:

Incorrect parameter setting of the minimum or maximum power.

Block

67:

A

T has been detected between fl ow and return sensor whereas the burner is not in operation.

After

the

T has disappeared the block will clear.

Block

85:

The control has not detected a water fl ow. The venting cycle is started.

If during this cycle water fl ow is detected, the venting cycle is ended and the burner is released.

Error

with a number in the last two positions.

Error

00:

Poor

fl ame-forming

Error

02:

no

fl ame-forming

Error 04: adjustment or error for voltage interruption

Error

05:

adjustment

Error 12: high limit stat

Error

18:

maximum

fl ow temperature exceeded

Error 19: maximum return temperature exceeded

Error 28: number of revolutions not reported back from fan

Error 69: no or incorrect display

FUSE:

24V fuse defective