Installation & Servicing Instructions Rinnai E-Series

23

The boiler has a self-adjusting and self-protecting control system for the load and the
pump capacity. By this means the temperature difference between the supply and return
water is checked and controlled.

If the installation resistance is over the stated value; the load will be adjusted until
an acceptable temperature difference between supply and return water has been
obtained. If, after this, the temperature difference is still not acceptable then the boiler
will switch off and wait until an acceptable temperature has arisen.
If an unacceptable temperature is detected, the control will repeatedly try to achieve
water fl ow over the boiler. If not the boiler will switch off.

As standard the boiler is provided with a water fi lter in the return pipe of the boiler, so
that debris of the central heating water is prevented from affecting the boiler.

The boiler is designed to be used on pressurized heating systems only.

pump

index

lines

graph

1

NOTICE

i

0

2

4

6

8

10

12

14

0

2

4

6

8

10

12

Q [gallons/min]

PSI

UPS 20-48

UPS 20-58

Resistance OSS1

Resistance OSS2

32.3

27.7

23.0

18.5

13.8

9.2

4.6

0

Feet of head

Resistance E75C

UPS 20-48 (25%)

UPS 20-58 (100%)

Resistance E110C

E75C
E110C

E75C

E1

10C

Water fi lter

fi gure 9a