Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

• This filter is not washable and cannot be regen-

erated, and must be replaced approximately every
four months of operation, or more frequently with
heavy usage.

• Remove the metal grease filters.
• Remove the saturated activated carbon filter by

releasing the fixing hooks.

• Fit the new filter by hooking it into its seating.
• Replace the metal grease filters.

Lighting

LIGHT REPLACEMENT

• 20 W halogen light.
• Remove the 2 Screws fixing the Lighting sup-

port, and pull it out of from the Hood.

• Extract the Lamp from the Support.
• Replace with another of the same type, making

sure that the two pins are properly inserted in the
lamp holder socket holes.

• Replace the Support, fixing it in place with the

two Screws removed as above.

FUSE REPLACEMENT

Fuse: model 5x20 5A time-delay
• Remove the filters.
• Remove the Screws fixing the fuseholder box.
• Open the fuseholder (bayonet fixing).
• Replace the fuse with another of the same type.
• Replace the fuseholder box and the filters.