Leakage checkpoints – Maytag HRX75XORSCGA Manuel d'utilisation

Page 26

Advertising
background image

26

“OFF” the entire gas supply to the water heater. Call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.

Leakage Checkpoints

Read this manual first. Then before checking the water heater
make sure the gas supply has been turned “OFF”, and never
turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with
water. To prevent damage to the tank, the tank must be filled
with water. Water must flow from the hot water faucet before
turning “ON” gas to the water heater, see Figure 28.

A. Water at the draft hood is water vapor which has condensed

out of the combustion products. This is caused by a
problem in the vent. Call Maytag Customer Service at
1-800-788-8899 for an authorized servicer.

B. *Condensation may be seen on pipes in humid weather or

pipe connections may be leaking.

C. *The anode rod fitting may be leaking.

D. Small amounts of water from the temperature-pressure relief

valve may be due to thermal expansion or high water pressure
in your area.

E. *The temperature-pressure relief valve may be leaking at the

tank fitting.

F. Water from a drain valve may be due to the valve being slightly

opened.

G. *The drain valve may be leaking at the tank fitting.

H. Combustion products contain water vapor which can

condense on the cooler surfaces of the tank. Droplets form
and drip onto the burner or run on the floor. This is common

at the time of start-up after installation and when incoming
water is cold.

I. Water in the water heater bottom or on the floor may be from

condensation, loose connections, or the relief valve.
DO NOT replace the water heater until a full inspection of all
possible water sources is made and necessary corrective
steps taken.

Leakage from other appliances, water lines, or ground seepage
should also be checked.

*

To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet, follow
“Draining” instructions in the Service and Maintenance section
and then remove fitting. Put pipe dope or teflon tape on the
threads and replace. Then follow Filling the Water Heater
instructions in the Locating and Installing the New Water
Heater
section.