PRODUCT DATA SHEETS

Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters)

This system has been tested according to NSF/ANSI

Standards 42 and 53

for the reduction of the substances listed below. The

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the

Standards 42 and 53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68 to

71.6 (2 C to 22

).

replacement requirements be carried out for the product to

perform as advertised.

’s rated life is used, the yellow (Order)

’s rated life is used,

the red (Replace) light comes on, and it is recommended that

The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after

Refer to the back cover or “Accessories” section for the

Manufacturer ’s name, address and telephone number.

Application Guidelines/Water Supply Parameters

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,

Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

Substance Reduction

NSF Reduction

Requirements

Average

Concentration

Maximum

Average

Minimum%

Reduction

Average%

Reduction

Chlorine Taste/Odor

Particulate Class I

*

50% reduction

85% reduction

1.88 mg/L

5,700,000 #/mL

2.0 mg/L ± 10%

At least 10,000

particles/mL

0.06 mg/L

69,000 #/mL

**

0.05 mg/L

30,583 #/mL

96.84

98.94

>97.26

99.52

Contaminant

Reduction

NSF Reduction

Requirements

Average

Concentration

Maximum

Average

Minimum%

Reduction

Average%

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

0.010 mg/L

0.010 mg/L

0.153 mg/L

0.150 mg/L

0.15 mg/L ± 10%

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.29%

>99.35%

>99.33%

Mercury: @ pH 6.5

Mercury: @ pH 8.5

0.002 mg/L

0.002 mg/L

0.006 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.006 mg/L ± 10%

0.0005 mg/L

0.0015 mg/L

0.0003 mg/L

0.0008 mg/L

90.91

75.93

95.70

86.22

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L

75.31%

76.99%

Asbestos

99%

155 MF/L

10

7

to 10

8

††

<1 MF/L

<1 MF/L

>99.99%

>99.99%

Live Cysts

Turbidity

>99.95%

0.5 NTU

166,500 #/L

10.7 NTU

50,000/L min.

11 ± 1 NTU

<1 #/L

0.49 NTU

<1 #/L

0.31 NTU

>99.99

95.2

>99.99

97.09

Lindan

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
35 - 100 psi (241 - 689 kPa)
33 - 10

F (1 - 38 C)

0.78 gpm (2.9 L/min.) @ 60 psi.

*

**

††

Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

Advertising