Mustang Survival MD4020 Manuel d'utilisation

Inflatable pfd re-arm kit, Md4020, Ma 4013

Advertising
background image

CAP

Figure 4

INFLATOR BODY

SEALING RING

RED
INDICATOR

Figure 6

GREEN
INDICATOR

CAUTION:
DO NOT TURN
THE CENTER
SHAFT

Figure 7

SINGLE
POINT INDICATOR

WATER
INLET VALVE

Figure 9

BLACK
LOCKING RING

Figure 8b

90º

Figure 8a

Figure 5

RED INDICATOR

TRASH

Inflatable PFD Re-arm Kit

VFI Gonflable Ensemble De Réarmement

Re-arm kit for Mustang survival PFD:
Ensemble de réarmement pour modèle de

V.F.I. de Mustang survival:

MD4020

Inflatable PFD Re-Arm Kit

MA4013

Mustang survival

MA4013

Figure 3

Figure 1

LOCKING RING KEY

Figure 2

WARNING

· Use only with specified PFD models.
· This gas cylinder is under pressure, therefore

misuse can be dangerous.

· Do not incinerate, expose to sunlight or store

above 120˚F (50˚C).

· Do not throw into open fire or dump at sea.
· Keep away from children.
· Dispose of gas cylinders only when empty.
· Discharge and dispose of corroded or rusty

cylinders.

IMPORTANT

Please review and follow additional maintenance
instructions in your Owner’s Manual.
The Damage Tolerant Life Preserver is equipped
with two cylinders. Please inspect both to ensure
proper operation.

Re-arming instructions

1. Place the Inflatable PFD on a smooth, flat

surface and wipe off any water. Access the

inflator by reaching under the cover and pull

it toward you, turning the cell and cover inside

out to fully expose the inflator for re-arming.

At this time, ensure that the inside of the

bladder is dry. Hold the CO2 cylinder through

the fabric, using one hand (Fig. 1).

2. Insert the metal key between the black locking

ring and labeled yellow cap. Turn the key

counter-clockwise (Fig. 2).

3. Turn the black locking ring counter-clockwise

and lift off the cap (yellow inflator operating

head Fig. 3). Dispose of the used cap.

4. Squeeze the sealing ring to elongate and

remove the inflator body through the sealing

ring (Fig. 4).

5. Dispose of the used inflator body (Fig. 5).

6. Check that the new inflator body indicator is

green. Insert the new inflator body with CO2

cylinder pointing upward inside the Inflatable

PFD. Let the sealing ring rest on the adapter

around the four lugs (Fig. 6).

7. Now check the new manual/automatic cap as

follows (Fig. 7):

1. Is the single point status indicator showing
green?

2. Is the expiry date OK?

If YES is the answer to both questions, then

proceed as follows.

If the answer is NO to either question, get a new cap.

8. Hold the CO2 cylinder through the fabric

of the Inflatable PFD (Fig 8a). Position the

replacement cap with the water inlet valve

pointing to the right and press firmly onto the

inflator body and sealing ring (Fig. 8b).

9. While pressing FIRMLY onto the inflator body,

turn the BLACK locking ring clockwise into the

locked position (Fig. 9). Pull on the cap to make

sure it has locked onto the inflator body.

10. Check: To see that the single point status

indicator on the cap is green; the pull to

inflate lanyard is present and that the locking

ring is locked.

11. If your Inflatable PFD has been used and/or

the inflator replaced, always inflate through

the oral tube and check that it stays inflated

at least overnight. Empty the Inflatable PFD

again by reversing the oral-inflation tube

dust cap and inserting it into the valve or by

depressing the valve with fingertip. Gently

squeeze the inflatable PFD until all air or gas

has been expelled. Let the Inflatable PFD dry

before packing.

IMPORTANT: Ensure all air is removed before

repacking.

12. Refold the Inflatable PFD in accordance with

the Repacking section of the owner’s manual.

PA4013_Rearm_10Apr2007.indd 1-5

4/26/2007 4:15:19 PM

Advertising