Work like a pro – Miller Electric Blue Star 3500 Manuel d'utilisation

Page 23

Advertising
background image

OM-498 Page 19

Return To Table Of Contents

6-3.

Description Of Controls (Honda-Powered Units) (See Section 6-2)

.

Weld and generator power output stops if
generator overheats or engine speed is
too low.

1

Engine Switch

On models with recoil-start, use switch to
open ignition circuit, and to stop engine.

On models with electric-start, use switch to
open ignition circuit, and to start and stop en-
gine.

2

Throttle Control Lever

Use lever to select engine speed. Move lever
to idle position (far right) for idle speed. Move
lever to Run position (far left) for weld/power
speed.

.

Always place lever in Run position (far
left) for generator power and for maxi-
mum weld output.

3

Choke Control Lever

Use lever to change engine air/fuel mix. Move

lever to left if starting a cold engine. Move le-
ver to right if starting a warm engine.

4

Starter Handle (Recoil-Start Models
Only)

To Start (Recoil): open fuel valve, turn engine
switch to On, move throttle lever to Idle, set
choke, and pull starter handle. Open choke as
engine warms.

To Start (Electric): open fuel valve, move
throttle lever to Idle, set choke, and turn en-
gine switch to Start position. Open choke as
engine warms.

Y

If the engine does not start, let engine
come to a complete stop before at-
tempting restart.

To Stop: turn engine switch to Off.

.

Always close fuel valve after stopping
unit. Moving unit with fuel valve open may
cause carburetor flooding and make
starting difficult.

5

Welding Range Label

Use label to determine correct weld amper-
age based on electrode size, type, and mate-
rial thickness.

6

Current Control

Use control to select weld amperage. Control
may be adjusted while welding.

To Set Current Control: Use label to deter-
mine correct size electrode for material thick-
ness. Select electrode type and set current
control to corresponding amperage range on
nameplate. Adjust control within selected
range to obtain desired weld performance.

EXAMPLE:

Material Thickness: 1/8 to 1/4 in

Electrode Diameter: 1/8

Electrode Type: E-6013

Current Control Setting: 90 − 120 A

Notes

Work like a Pro!

Pros weld and cut

safely. Read the

safety rules at
the beginning
of this manual.

Advertising