background image

OM-498 Page 15

Return To Table Of Contents

5-5.

Engine Prestart Checks (Honda-Powered Units)

Ref. 802 099-A

Full

Full

Gasoline

1/2 in

(13 mm)

Check all fluids daily. Engine must
be cold and on a level surface. Unit
is shipped with 10W30 engine oil.

Engine stops if oil level gets too low.

1

Fuel Valve

Open valve.

.

Close fuel valve before moving
unit or carburetor may flood
and make starting difficult.

Fuel

Add fresh fuel before starting
engine the first time (see mainte-
nance label for specifications). Fill
fuel tank up to 1/2 in. (13 mm) from
top to allow room for expansion.
Check fuel level on a cold engine
before use each day.

Oil

After fueling, check oil with unit on
level surface. If oil is not up to full
mark on dipstick, add oil (see main-
tenance label).

.

To improve cold weather
starting:

Keep battery in good condition.
Store battery in warm area off
concrete surface.

Use correct grade oil for cold
weather.

1

Open

5-6.

Connecting The Battery (Honda Electric-Start Models Only)

802 100-A / Ref. S-0756-D

3/8, 1/2 in

Tools Needed:

+

Y

Connect negative (−)
cable last.

Y

Turn Engine Switch to Off
(electric-start models only).