PREPARE HOT WATER LINE

• The line may enter from either side, rear or floor

within the shaded area shown in Figure F.

• The line may pass through the same hole as the

electrical cable and drain hose. Or, cut an additional
1-1/2" dia. hole to accommodate the water line.
If power cord with plug is used, water line must
not pass through power cord hole.

Water Line Connection

• Turn off the water supply.
• Install a hand shut-off valve in an accessible location,

such as under the sink. (Optional, but strongly
recommended and may be required by local codes.)

• Water connection is on the left side of the dishwasher.

Install the hot water inlet line, using no less than 3/8"
O.D. copper tubing. Route the line as shown in Figure F
and extend forward at least 19" from rear wall.

• Adjust water heater for 120°F to 150°F temperature.
• Flush water line to clean out debris.
• The hot water supply line pressure must be 20-120 PSI.

Installation Instructions

7

Cabinet Face

Shut-off

Valve

2" From Floor

19" From Wall

2"

From

Cabinet

1-1/2" Dia.

Hole

Hot

CAUTION

Do not remove wood base until you are ready

to install the dishwasher. The dishwasher will tip over
when the door is opened if the wood base is removed.

BEFORE YOU BEGIN

Locate and set aside (for use in Step 12) the
2 Phillips special head screws wrapped with

yellow tape and stuck to the top or side of the
dishwasher. Remove drain hose from upper rack, if
it has not been pre-installed, and set aside for use in
Step 7.

Figure F

CHECK DOOR BALANCE

• With dishwasher on the wood skid, check the door

balance by opening and closing the door.

• If the door drops when released, increase the spring

tension. If the door rises when released, decrease
the tension.

NOTE: The addition of the custom panel on model
ZBD6890 will require exchange of the factory installed
springs. Use the heavy-duty springs provided. See the
custom panel template for additional instructions.
• Position the spring for increased or decreased

tension as required.

NOTE: Adjust both balance springs to the same
amount of tension to prevent excessive door
twisting during use.

TIP: If door does not open easily or falls too quickly,
check the spring cable routing. Check that the cable
is properly aligned on the pulley (as shown).

STEP 1

Correct Spring

Cable Routing

Increase

Tension

Decrease

Tension

Pulley

Shoulder

Use This

Mounting

Hole

Figure G