Installation requirements, Clearance requirements, continued, Installation in a recess or closet – FRIGIDAIRE 137112300B Manuel d'utilisation

Page 10

Advertising
background image

10

INSTALLATION REQUIREMENTS

Clearance requirements, continued

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES

REAR

TOP

FRONT

Alcove

0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

Under-

Counter 0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

Closet

0” (0 cm) 0” (0 cm)* 0” (0 cm) 1” (2.54 cm)

0”

(0cm)

0”

(0cm)

1”

(2.54cm)

0”

(0cm)

For other than straight back venting, a quick-turn

*

90° dryer vent elbow (vented right or down in free-

standing dryer or right on pedestal-mounted dryer)

must be installed to achieve 0” (0 cm) installation.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Installation in a Recess or Closet

1 A dryer installed in a bedroom, bathroom, recess or

closet, MUST be exhausted outdoors.

2 No other fuel burning appliance shall be installed in

the same closet as the gas dryer.

3 Your dryer needs the space around it for proper

ventilation.

DO NOT install your dryer in a closet with a solid door.

4 Closet door ventilation required: A minimum

of 120 square inches (774.2 cm²) of opening,

equally divided at the top and bottom of the

door, is required. Openings should be located 3

inches (7.6 cm) from bottom and top of door.

Openings are required to be unobstructed when a

door is installed. A louvered door with equivalent

air openings for the full length of the door is

acceptable.

Í

NOTE

To achieve an installation with 0” (0 cm) clearance

for the back of the dryer (for other than straight back

venting), a quick-turn 90° dryer vent elbow must be

installed as described previously in this manual.