Version 3/08 - Page 7

1. Put a thick, protective covering

over cooktop, set-in range

or countertop to protect from

damage or dirt.

2. Determine and clearly mark

with a pencil on the ceiling where

the rangehood will be installed.

3. A template (L in FIGURE 6) for

mounting the support is supplied

in the carton with the support.

Use this template to mark holes

for support on the ceiling.

.

ATTACH THE SUPPORT

4. Determine and make necessary cuts for the ductwork. The

duct opening is shown on the mounting template (L in FIGURE

6). Install ductwork before mounting the support.

IMPORTANT NOTE: BE CAREFUL WHEN DETERMINING THE

LOCATION FOR THE HOLE IN YOUR CEILING FOR THE DUCT

WORK. THIS HOLE SHOULD NOT BE CENTERED OVER THE

CENTER OF THE COOKING SURFACE AS THE DUCT WORK

THAT RUNS UP INSIDE THE CHIMNEY AND THROUGH THE

CEILING IS NOT IN THE EXACT CENTER OF THE CHIMNEY.

5. Determine the proper location for the Power Supply Cable as

indicated on the template. Use a 1 1/4" Drill Bit to make this hole.

Run the Power Supply Cable. Use caulking to seal around the hole.

DO NOT turn on the power until installation is complete! A

knockout is provided at the top of the UPPER CHIMNEY SUPPORT

(E in FIGURE 7).

6. For ducted installations, place the round DAMPER (A in FIGURE

7) into the exhaust opening of the rangehood and press down.

7. Before attaching the support to the ceiling, you must determine

the desired length of the support structure and adjust the length of

the support by removing the eight screws (indicated in FIGURE

7) with a flat head screwdriver. Once the length of the support is

determined, install and tighten the eight screws.

FIGURE 7

FIGURE 6

FIGURE 8

As indicated in FIGURE 8, place the FLANGE (A) into the

exhaust opening of the rangehood and press down. Fit the

DUCTLESS DIVERTER EXTENSION VERTICAL (B) over the

FLANGE (A) and fit the DUCTLESS DIVERTER (C) over the

EXTENSION (B). Fit the DUCTLESS DIVERTER EXTENSION

HORIZONTAL (D) into the DIVERTER (C).

1. The UPPER CHIMNEY

COVER (C in FIGURE 9)

attaches using two screws

provided (G in FIGURE

9). Slide up and attach the

UPPER CHIMNEY COVER.

2. Attach the duct work to the

DAMPER (A in FIGURE 7).

Make sure to seal all joints with

duct tape to prevent leaks.

FIGURE 9

8. Slide the UPPER CHIMNEY COVER (C in FIGURE 1 for

ducted installations - the upper chimney that came with the

rangehood, or G in FIGURE 8 for ductless installations - the

upper chimney that came with the ductless kit) down over the

UPPER CHIMNEY SUPPORT (E in FIGURE 7) until it rests on the

motor box (D in FIGURE 7). Attach the entire support to the ceiling.

Make sure that the support is firmly attached to the ceiling.

MAKE THE ELECTRICAL CONNECTION

Remove the cover from the field wiring compartment. DO NOT

turn on the power until installation is complete! Connect

the Power Supply Cable to the rangehood. Attach the White

lead of the power supply to the White lead of the rangehood

with a twist-on type wire connector. Attach the Black lead of the

power supply to the Black lead of the rangehood with a twist-on

type wire connector. Connect the Green (Green and Yellow)

ground wire under the Green grounding screw.

FOR DUCTLESS INSTALLATIONS

Ductless installations require a Ductless Conversion Kit whose

components are pictured in FIGURE 8. Do not use the DAMPER

(A in FIGURE 7) for ductless installations. The LOWER CHIM-

NEY COVER (B in FIGURE 1) should be discarded and replaced

by the new one with the hole from the Ductless Conversion

Kit (F in FIGURE 8). The UPPER CHIMNEY COVER (C in

FIGURE 1) should be discarded and replaced by the shorter

one from the Ductless Conversion Kit (G in FIGURE 8).

3. The LOWER CHIMNEY COVER (B in FIGURE 9) rests

on the top of the CANOPY SECTION (A in FIGURE 1)

once it is installed. Install the LOWER CHIMNEY COVER

by sliding it up over the support.

For ductless installations, line up the DUCTLESS DIVERTER

EXTENSION HORIZONTAL (D in FIGURE 8) with the hole

in the LOWER CHIMNEY COVER (F in FIGURE 8) and

snap in the VENT GRID (E in FIGURE 8).

INSTALLING THE RANGEHOOD

Advertising