background image

43000-01 06/02/2006 © 2006 Hunter Fan Company

8

Boiler
Cover

Boiling
Chamber

Boiler

Base

4. Place the Boiling Chamber into an empty sink

and carefully lift the Boiling Chamber Cover

by pressing the Chamber Cover Release Tab.

This will expose the Heater. Drain all water

and rinse with cool, clean water. Use a soft

brush or sponge to clean the Boiling Chamber

and the Boiling Chamber Cover.

5. Pour one (1) cup of white vinegar into the

Boiling Chamber and allow it to soak for

20-30 minutes. Rinse several times with cool,

clean water. Wipe the Boiler clean if necessary.

6. Before reinstalling the Boiling Chamber, make

sure the three metal pins in the Chamber are

clean and completely dry. Place the Boiling

Chamber Cover into the Boiling Chamber and

slide the Chamber slowly back into place.

Make sure the Chamber fits properly in the

Base.

7. To disinfect the Water Tank, create a solution

of one (1) cup of white vinegar and one (1)

gallon of clean water. Fill the Water Tank

with the solution and allow it to soak for 20

minutes, occasionally swishing the solution to

wet all interior surfaces. Empty the Water Tank

completely and rinse with clean water several

times. Refill the Water Tank with cool, clean

water and place it back on the humidifier

Base.

8. NEVER use any metal or hard object, which

could cause scratching of the humidifier

surface, to clean plastic parts. NEVER use

gasoline, kerosene, glass cleaner, furniture

polish, paint thinner, or other household

solvents to clean any part of the humidifier.

9. The Water Tank should be drained EACH DAY,

rinsed, and refilled with clean tap water.

10. To clean the exterior surfaces, use a solution

of water and mild detergent with a damp

cloth. Rinse the surfaces with clean water and

dry with a cloth. Allow sufficient time to dry

before plugging the electrical cord back into

the outlet.

11. Place the Water Tank back onto the Base and

resume normal use.

Base

Water
Tank

43000_WM MechHum_06.02.06.indd

6/2/06, 11:16 AM

8

Advertising
Ce manuel est liée aux produits suivants: