Vacation, Checking your humidifier operation, Troubleshooting your humidifier – Honeywell HE120 Manuel d'utilisation

Page 6

Advertising
background image

HE120 BY-PASS DRUM HUMIDIFIER

69-1110EF—02

6

IMPORTANT

Be sure the humidifier power is off and the humidifier water pan is empty.

Vacation

When leaving on vacation, turn off the humidifier water supply and your humidity

control. Turn on the humidifier water supply and reset your humidity control when you

return.

CHECKING YOUR HUMIDIFIER OPERATION

After winter startup or maintenance, use the following steps to check the humidifier

operation:

1. Turn on the humidifier power and water supply.

2. Open By-Pass Damper (if installed).

3. Check the water level in the humidifier water pan; water level setting should be

1-3/8 in.

NOTE: Turn the valve adjustment screw, located on the water valve inside the

humidifier, clockwise to lower the water level and counter clockwise to raise it.

4. Turn the Humidity Control to the highest setting.

5. Check that the humidifier pad is rotating.

6. Reset the thermostat and Humidity Control to a comfortable setting.

TROUBLESHOOTING YOUR HUMIDIFIER

Problem

What To Look For

What To Do

Low humidity Furnace blower not

operating.

Reset circuit breaker or check for blown fuse.

Check that the furnace power is on.

Check all external wiring connections.

Check the humidity control setting.

Call a professional heating contractor.

Rapid air changes.

Drafts (cold air is dry

and is an added load

to the humidifier).

Keep doors and windows closed.

Close fireplace damper when not in use.

Keep exhaust fan running time to a

minimum.

Seal around doors and windows.

High humidity Condensation on

walls.

Turn off the humidity control and water until

condensation is completely evaporated.

Heavy condensation

on windows.

Turn humidity control down low enough to

eliminate condensation caused by moisture

from bathing, mopping, cooking, etc. If

moisture persists, more ventilation is

needed.

Advertising