HE120 BY-PASS DRUM HUMIDIFIER

5

69-1110EF—02

7. Refer to the drawing to disassemble the drum. See Fig. 3.

Fig. 3. Drum Assembly

8. Clean all humidifier parts in a 50% solution of vinegar (or a humidifier cleaner)

and water. Soak overnight to remove stubborn deposits.

NOTE: Replace humidifier pad yearly with the new Honeywell Drum Humidifier Pad

(Part no. HC12A1015). The actual frequency depends on the quality of the

water used.

9. After the humidifier components are clean, reassemble the humidifier by

reversing the order of steps 1 through 7.

NOTE: Be sure that the drum shaft is completely seated-listen for the click.

10. Verify the humidifier operation by following the steps in the Checking Your

Humidifier Operation section.

Start of Humidification Season

Replace the humidifier pad with a new Honeywell Drum Humidifier Pad (Part no.

HC12A1015) at the beginning of the heating season. Follow the cleaning instructions

to replace the pad and check for proper operation.

End of Humidification Season

Clean the humidifier and shut it off at the end of the heating season. Follow the

cleaning instructions, steps 1 through 9, to shut down the device for the season.

OPEN

DRUM END

CLOSED DRUM END

METAL TABS

TINNERMAN

DRUM SHAFT

PAD

SQUEEZE

SLIGHTLY

TO INSTALL

M13609