F300 ELECTRONIC AIR CLEANER

68-0240EF-5

6

Applications with a Humidifier

An evaporative humidifier can be mounted upstream from the

air cleaner. An atomizing humidifier should be mounted

downstream from the air cleaner, even though hard water salts

will be blown into the living space and deposited as dust. If an

atomizing humidifier must be mounted upstream from the air

cleaner:

1. Mount it as far as possible upstream from the air cleaner.

2. Install a standard disposable furnace filter between the

humidifier and the air cleaner to trap water droplets and

hard water salts.

3. Frequently clean the air cleaner to prevent a hard water

salt buildup.

NOTE: The volume of water that is discharged from an atom-

izing humidifier can overload the air cleaner, resulting

in hard water salts being deposited as dust in the liv-

ing space.

Applications with Outdoor Air Intake

Return air temperature must be at least 40°F (4°C). Lower

temperatures can cause ionizer wire failure. If outdoor air is

used, warm it upstream from the air cleaner by:

• Making sure the outdoor intake is far enough upstream from

the air cleaner so the return and outdoor air is thoroughly

mixed. Stratified air can dump a stream of very cold air into

one section of the air cleaner.

• Adding baffles upstream from the air cleaner to force

thorough air mixing.

• Installing a Honeywell Perfect Window™ Fresh Air

Ventilation System that transfers up to 80 percent of the

heat from the exhaust air to the incoming outside air. This

keeps the incoming air above 40°F (4°C) and reduces

energy usage.

• Installing a preheater if large amounts of outdoor air are

used. The preheater, which could be an electric strip heater

or hot water coil, should be controlled by a thermostat. Hot

water or steam coils should be protected by a freeze-up

control.

Optional W8600F Air Cleaner Monitor

The W8600F Air Cleaner Monitor can be mounted in the living

area or in the furnace room. It should be located in a

convenient location to observe the display.

The W8600F Air Cleaner Monitor is furnished with all the

connectors needed for easy installation. Follow the installation

instructions provided with the W8600F.

Optional W8600A AIRWATCH™ Indicator

The W8600A can be mounted next to the thermostat or in any

other location in the living area of the home where the display

can be conveniently observed. No wiring is necessary.

Choose Location

Choose a location that is readily accessible for regular

inspection and cleaning. Allow at least 13 in. (330 mm) in front

of the access door for removing the metal mesh prefilter, media

postfilter and electronic cell. Allow enough room above the

power supply so it can be serviced without removing pipes,

ducts, or other heating system components.

The air cleaner must be installed where the temperature is

between 40° to 125°F (4° to 52°C).

IMPORTANT

UV light can damage media postfilters. Avoid

installing UV lamp downstream of F300 in location

where UV light illuminates postfilter.

Choose Mounting Position

WARNING

Heavy Equipment Hazard.

Can cause injury or equipment damage.

Do not mount air cleaner with access door facing down

because the latch may not hold and the cell, postfilter

and prefilter can fall unexpectedly.

NOTE: Nothing holds the cell, postfilter, and prefilter in place

when the access door is opened.

The air cleaner can be mounted in any position except with the

access door facing down. A list of air cleaner mounting

positions for a variety of furnace installations follows.

NOTE: At least 13 in. (330 mm) clearance is required

between the access door and any obstructions for

cell, postfilter and prefilter maintenance.

— Upflow Highboy furnace: Side installation; air cleaner is

mounted vertically where return enters side inlet of furnace.

See Fig. 3A.

— Upflow Highboy furnace: Installation beneath furnace (air

cleaner cabinet can easily support weight of furnace and air

conditioner coil). Air cleaner is mounted horizontally where

return enters from below. See Fig. 3B.

— Upflow Highboy furnace: Closet installation. Air cleaner is

mounted vertically on furnace between furnace and

louvered return air opening in closet door. See Fig. 3C.

— Lowboy furnace: Air cleaner is mounted horizontally in

return plenum just above furnace, opposite of supply

plenum. See Fig. 3D.

— Downflow Counterflow furnace: Air cleaner is mounted

horizontally in return duct or plenum just above furnace.

See Fig. 3E.

— High capacity system: Two or more air cleaners can be

used together. See Fig. 3F.

— Horizontal furnace: Air cleaner is mounted vertically where

return enters. See Fig. 3G.