Operating Instructions and Owner’s Manual

enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters

1. general inFOrMatiOn

Your heater comes fully assembled and is tested at

a.

the factory for proper gas and input as stated on
the name plate.
Before proceeding with the installation, be sure to

b.

inspect for damages. Freight company must be noti-
fied of any damages and request that an inspection
be made by the freight company. HeAT STAR will send
replacement parts for damaged parts only after receiv-
ing a signed inspection report to prove the liability of
the freight company.
Do not attempt to operate heater with any other gas

c.

than that indicated on the heater name plate.
The installation of heater must conform with local

d.

building codes or, in absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1a/NFPA54. In
Canada, refer to Can 1-B146.1 and B149.2.
Plugged 1/8” N.P.T. Test Gage Connection is located

e.

on the Heater Gas Control or a ¼” N.P.T. Connection is
located on the outside of the Cast Venturi.

2. clearances Minimum clearances to combustibles.

(refer to Figure 1)
Provide adequate clearance to combustibles, Figure 1,
between control end of heater for servicing and mini-
mum on top and sides for ventilation and combustion
air supply.
A minimum clearance of 8’ above floor for public
garages in accordance with ANSI/NFPA No. 88 most re-
cent edition or Figure 1; whichever is larger. In Canada
refer to Can 1-B149.1 and B149.2 Installation codes for
Gas burning appliances.
A minimum clearance of 10’ from the bottom of heater
to top of wing, or engine enclosure, where aircraft are
housed, and 8’ above floor in other areas of the hang-
er in accordance with ANSI/NFPA No. 409 most recent

Figure 1

MoDel No.

BTU/HR. RATING

NoRMAl

MoUNTING

PoSITIoN

CleARANCeS To CoMBUSTIBleS

GAS

NATURAl

PRoPANe

ToP

SIDeS

BACK

BeloW

4030**

30,000

30,000

Horiz.-45°

30”

30”

30”

54”

4040*

40,000

40,000

Horiz.-45°

34”

30”

30”

68”

8050**

50,000

50,000

Horiz.-45°

36”

30”

30”

78”

8060*

60,000

60,000

Horiz.-45°

40”

30”

30”

84”

8070**

70,000

Horiz.-45°

40”

30”

30”

84”

9080**

80,000

80,000

Horiz.-45°

46”

40”

40”

104”

9090**

90,000

90,000

Horiz.-45°

46”

46”

46”

114”

9100S*

100,000

100,000

Horiz.-45°

48”

46”

46”

118”

9100**

100,000

100,000

Horiz.-45°

44”

40”

40”

104”

9120*

120,000

120,000

Horiz.-45°

46”

46”

46”

114”

9140**

140,000

Horiz.-45°

16”

46”

46”

114”

edition, or Figure 1; the larger dimension of ANSI/NFPA
No. 409 or Figure 1 is to be used. In Canada refer to
CCA B149-1-M91 and B149.2.

warning:

MAINTAIN CleARANCeS AS SHoWN

IN FIGURe 1 oR oN HeATeR NAMePlATe, IN GARAGe
INSTAllATIoNS WHeRe PARKeD VeHICleS ARe DI-
ReCTlY BeloW THe HeATeR.

3. suspensiOn

Heater has four mounting holes, two on each end, for
attaching rod or angle iron brackets and shall be safely
and adequately fixed in position independent of gas
and electric supply lines. Refer to Figures 4, 5, and 7 on
pages 13 and 14 for recommended suspensions.

4. gas supplY

Provide adequate gas supply for rated input of each
heater using American Standard Installation of gas
piping and gas appliances in building ANSI/223. 1a/
NFPA54 Pamphlet, Table C-3 shows capacity of pipe of
different diameters and lengths in cubic feet per hour
for Natural Gas with pressure drop of 0.3 inches specify
gravity of 0.60. For liquefied Petroleum Gas (LP) capac-
ity refer to Table C-3 and C-15 of the same pamphlet.
For recommended heater gas connection refer to
Figure No. 5, Page 15. In Canada refer to Can 1-B149.1
and B149.2, and CSA sto. B63.
If gas lines are to be pressure tested with compressed
air, disconnect each heater to prevent control damage
and cap outlets. After reconnecting all heaters, purge
gas lines of air and check all connections for leaks us-
ing soap solution.

warning:

Do NoT USe MATCH oR oTHeR

FlAMe FoR leAK TeSTING.

5. gas pressure

When a higher than the maximum recommended
gas pressure is being maintained at the main gas line,

*High Intensity Heaters are only sold as 4040, 8060, 9100S, and 9120
**Different model numbers are achieved by using supplemental orifices included with heaters to change heat output.