replacing timer batteries

Batteries must be replaced when the Turbo does not respond to commands sent
by the timer (low or discharged batteries). Replace the batteries with 2 new lr3
alkaline batteries.

filter cleaning

The Turbo is equipped with a dust filter which will stop the Turbo when it is satu-
rated (see «Thermal safety»).
Filter indicator 1 lights steady red after 200 hours of use. In this case the blower will
stop working and the filter must be cleaned. Blower indicator 2 will remain steady
green regardless of the commands from the timer or infrared transmitter.
important: Power to the device must remain on for the filter cleaning alarm to be
turned off. (pictogram Nº5):

3 - Clean the filter using a vacuum or by
rinsing under water.

4 – Reposition the filter in the same way
as shown in Figure 2, by sliding to the
left or right.

5 – Press the Start / Stop button for 3
seconds. This will turn off the alarm.
The filter alarm will be triggered again
after 200 hours of use.

These pictograms show the procedure for cleaning the filter on the Turbo filter itself.

1 - Filter cleaning alarm:
FILTER indicator steady red.

2 - Remove the filter by sliding to the
left or right of the appliance.