Radson Turbo Manuel d'utilisation

Turbo 1000 watt, Specific cases, Timer on hot water version devices

Advertising
background image

1

Starting the device:

Press the button 5 on the side of the Turbo to turn the
device on (Turbo + towel dryer).
• Indicators 2 and 3: Steady green - Turbo + Towel dryer
turned on
• Filter indicator 1: Off
• Indicator 3: Steady red - towel dryer running

Blower 2 operating light:

• Off: Power Off
• Steady green: Power On
• Blinking red: Operating

turBo 1000 watt

the turbo is designed to quickly raise the temperature in your bathroom.

• Install the timer in the same room as the towel dryer. The
timer must be installed about 1.5 metres above the floor,
on an inside wall, away from splashing water, direct
sunlight and direct source of direct thermal disturbance.

note: To ensure proper infrared transmission:
- Do not obstruct transmitter and receiver cells
(bath towels in front of the cell).
- Avoid using electronic ballast lighting in the same room.

• Set the dial for the desired time and press the “OK / Boost”
button to start the blower.

note: Forced operation of the device can be interrupted at
any time by pressing the “OK / Boost” button again. When
restarting the blower in this case, the remaining Boost time
will be the setting shown on the dial.

infrared receiver on turbo

uK

1. Filter cleaning indicator
2. Blower operation indicator
3. Towel dryer operation indicator
4. Infrared receiver cell
5. Start/towel dry button

Specific caSeS

overheating

If towels or any other obstructions block the Turbo outlet
excessively, causing overheating, the device will shut down
(indicators 2 and 3 blinking red / green). The Turbo operation
will restart once the temperature cools, for the remaining
preset length of time.

thermal safety:

If the Turbo resistor overheats a manually reset thermal
safety device mechanically stops blower operation.

indicator light status:
• Filter indicator 1: Blinking red and
• Blower indicator 2: Steady green

important: A dirty filter can cause overheating. Clean it if
necessary. Press button 5 “start/stop” for 5 seconds to stop
this alarm.

note:
Please clean the filter each time the Clean Filter alarm
is triggered (“see Cleaning the Filter”).

caution: if the cause of overheating has not been identified
the alarm will be triggered again. In this case, please contact
the installer since this may cause the Turbo to deteriorate
over time.

The infrared timer trans-
mitter lets you send a start
command to the Turbo for
a variable period of 0 to 2
hours.

timer on hot water verSion deviceS

2

1

4

3

5

Advertising