11 device information, E-9 english 11 – Dimplex LIK 8MER Manuel d'utilisation

Page 10

Advertising
background image

E-9

English

11

11 Device Information

1

Type and order code

LIK 8MER

2

Design

2.1

Model

Compact

2.2

Degree of protection according to EN 60 529 for compact devices
and heating components

IP 20

2.3

Installation location

Indoors

3

Performance data

3.1

Operating temperature limits:

Heating water flow/return flow

°C / °C

Up to 58 / above 18

Cooling, flow

°C

+7 to +20

Air (heating)

°C

-25 to +35

Air (cooling)

°C

+15 to +40

3.2

Temperature spread of heating water at A7 / W35

10.0

5.0

3.3

Heat output / COP

at A-7 / W35

1

kW / ---

1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting

capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C
and heating water flow temperature 55 °C.

5.8 / 2.7

5.5 / 2.6

at A-7 / W45

1

kW / ---

5.4 / 2.1

at A2 / W35

1

kW / ---

7.5 / 3.3

7.4 / 3..2

at A7 / W35

1

kW / ---

9.3 / 3,9

9.2 / 3.8

at A7 / W45

1

kW / ---

8.8 / 3.2

at A10 / W35

1

kW / ---

9.8 / 4.1

9.7 / 4.0

3.4

Temperature spread of cooling water at A35 / W7

7.5

5.0

3.5

Cooling capacity / COP

at A27 / W7

kW / ---

7.9 / 2.7

7.9 / 2.6

at A27 / W18

kW / ---

9.6 / 3.2

9.6 / 3.2

at A35 / W7

kW / ---

7.0 / 2.0

6.9 / 2.0

at A35 / W18

kW / ---

8.5 / 2.4

8.5 / 2.4

3.6

Sound power level device / outdoors

dB(A)

53 / 60

3.7

Sound pressure level at a distance of 1 m (indoors)

dB(A)

48.0

3.8

Heating water flow with an internal pressure differential of

2

m³/h / Pa

2. The heat circulating pump is integrated.

0.8 / 2700

1.6 / 11900

3.9

Free pressure, heating circulating pump (heating, max. stage)Pa

45000

27000

3.10 Cooling water flow with an internal pressure differential of m³/h / Pa

0.8 / 2700

1.2 / 6500

3.11 Free pressure, circulating pump (cooling, max. stage)

Pa

45000

37000

3.12 Air flow rate with an external static pressure differential of m³/h / Pa

2500 / 20

3.13 Refrigerant; total filling weight

type / kg

R404A / 3.3

3.14 Output of electric heating element (second heat generator)kW

2.0

4

Dimensions, connections and weight

4.1

Device dimensions

H x W x L cm

190 x 75 x 68

4.2

Device connections to heating system

Inch

G 1'' external

4.3

Air duct inlet and outlet (min. internal dimensions)

L x W cm

44 x 44

4.4

Weight of the transportable unit(s) incl. packing

kg

250

4.5

Buffer tank volume

l

50

4.6

Buffer tank pressure rating

bar

6

5

Electrical Connection

5.1

Nominal voltage; fuse protection

V / A

230 / 20

5.2

Nominal power consumption

1

A2 W35

kW

2.27

2.33

5.3

Starting current with soft starter

A

30

5.4

Nominal current A2 W35 / cos

ϕ

A / ---

12.3 / 0.8

12.7 / 0.8

6

Complies with the European safety regulations

3

3. See CE declaration of conformity

7

Additional model features

7.1

Defrosting

Automatic

Type of defrosting

Reverse cycle

Defrosting tray included

Yes (heated)

7.2

Heating water in device protected against freezing

4

4. The heat circulating pump and the heat pump controller must always be ready for operation.

Yes

7.3

Performance levels

1

7.4

Controller internal/external

Internal

Advertising