Caractéristiques techniques, Copper specifications, Continued) – EXFO MaxTester 635 Manuel d'utilisation

Page 341

Advertising
background image

Caractéristiques techniques

Testeur de cuivre et de services multiples VDSL2/ADSL2+

333

COPPER SPECIFICATIONS

a, b, c

(continued)

Power spectral density (PSD)

Test type

Continuous with peak-hold

Vertical scale

15 dBm/Hz to –140 dBm/Hz or 20 dBm to –90 dBm

Horizontal scale

4.3125 kHz to 17 MHz, in 4.3125 kHz steps or
8.625 kHz to 30 MHz, in 8.625 kHz steps

Noise filters

None or E, F, G, ADSL2+, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30

Wideband impulse noise

Threshold

–50 dBm (40 dBrn) to 0 dBm (90 dBrn) in 1 dB steps

Counter maximum

65 000 000

Test duration

Maximum 100 hours

Uncertainty (accuracy) (dB)

±2

Noise filters

None or E, F, G, ADSL2+, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30

Wideband longitudinal balance

Level range (dB)

0 to 50 up to 2.2 MHz
0 to 40 up to 12 MHz

Level resolution (dB)

0.1

Level uncertainty (accuracy) (dB)

±2 (up to 2.2 MHz)

Frequency uncertainty (accuracy) (ppm)

±(50 ppm + 1 digit)

Frequency scale

ADSL/2+: 20 kHz to 2.2 MHz
VDSL/VDSL2-12: 20 kHz to 12 MHz

Single-ended frequency response
(attenuation)

d

Distance range (m)

100 m to 5000 m (300 ft to 16000 ft)

Frequency range (Hz)

4.3 kHz to 30 MHz

Frequency uncertainty (accuracy)

± (50 ppm + 1 digit)

Level uncertainty (accuracy) (dB)

± 2.0 dB typical for 2.2 MHz and 8 MHz ranges
± 3.0 dB for VDSL2-12 and VDSL2-17
± 4.0 dB for VDSL2-30 ranges

Resolution (dB)

0.1

Horizontal scale (MHz)

ADSL2+ = 2.208, VDSL2-8, VDSL2-12 = 12, VDSL2-17 = 17.66,
VDSL2-30 = 30

Vertical scale (dB)

0 to +100

Resistive fault location (RFL)

Test type

Single pair (two wire) and separate good pair (four wire)

Fault detection (M

1)

0 to 20

Resolution

Three digits

Loop resistance (k

1)

10 maximum

Multiple cable sections

Five (includes gauge and temperature setting)

Fault location

Total resistance, near-end to fault resistance, fault to strap resistance
(three significant digits, least significant digit 0.1

1)

Total length, distance to fault, distance from fault to strap
(three significant digits, least significant digit 1 m)

Uncertainty (accuracy)

±(0.1

1 + 1 % x RTS)

NOTES

a. Subject to change without notice.

b. Typical, at 23 °C ± 3 °C, on batteries, with no type B USB connection.

c. Specifications based on 24 AWG (PE 0.5 mm) cabling.

d. Specification based on 1 kft 24 AWG cabling. Range depends on cable type and condition.

Advertising