Maintenance

Detail

Item

Check

Replace

Notes

Maintenance Chart

Product safety
labels

Trigger adjust-
ment

Airless hose

Suction tube

Bypass tube

Suction filter

Gun filter

Roller nap

Outlet valve

Spray tip

Before each use

Before each use

Before each use

Before each use

Before each use

Before each use
and every 5 gal.

Before each use

Before each use

Before each use

As required

As required

As required

Every 100 gal.
or more often if
required

Every 100 gal.

As required

Every 100 gal.

Every 20-75 gal.

See parts listing for
location of product
safety labels and relat-
ed part numbers.

Make sure gun shuts
off while spraying.

Read information on
the hang tag attached
to the high pressure
hose for instructions
on maintenance.

Check for nicks and
cuts.

Check for nicks and
cuts.

Do not attempt to
clean gun filter, only
replace.

Use 3/4” wrench –
torque to 150 in-lbs.

Use 13/16” wrench –
torque to 135 in-lbs.