Maintenance – Craftsman MGP-670070 Manuel d'utilisation

Page 17

Advertising
background image

17 — ENG

MGP-670070

MAINTENANCE

CONNECTING ELECTRICAL LOADS

Let engine run and warm up for five minutes after
starting with no electrical load.

Connect loads in the following manner to prevent
damage to equipment:

Connect inductive load equipment first, inductive
loads consist of refrigerators, freezers, water
pumps, air conditioners, or small hand tools.
Connect the items that require the most wattage
first.

Connect the lights next.

Voltage sensitive equipment should be the last
equipment connected to the generator. Plug
voltage sensitive appliances such at TV's, VCR's,
microwaves, ovens, computers, and cordless
telephones into a UL listed voltage surge protec-
tor, then connect the UL listed voltage surge
protector to the generator.

IMPORTANT: You should always add up the rated
watts of all lights, tools and appliances you are
powering at one time. This total should not
exceed the rated capacity of you generator or
circuit breaker rating of the receptacle supplying
power.

CUSTOMER RESPONSIBILITIES TABLE

Note 1: Change oil after first five (5) operating hours, every 25 hours if operating under heavy load or high ambient
temperature, and every 50 operating hours thereafter.

Note 2: Clean more often under dusty conditions.

MAINTENANCE TASK

Every 25

Hours of Every

Season

Every 50

Hours of Every

Season

Every 100

Hours of Every

Season

Check oil level

Change oil

Change oil filter

Service air pre-cleaner

Service air cleaner cartridge

Spark arrester ( if equipped)

Clean cooling system

Check spark plug

Replace in-line fuel filter

GFCI (ground fault circuit interrupter)

Prepare unit for storage

Prepare unit for storage if it is to remain idle for more than 30 days.

Every 8

Hours or

Daily

X

X

See Note 1

See Note 2

X

X

X

X

See Note 2

See Note 2

Monthly

Advertising
Ce manuel est liée aux produits suivants: