TROUBLESHOOTING YOUR WINE CELLAR

15

Problem

Possible Cause

Remedy

Unit not cold enough.

Adjust temperatures (See “Set Tem-

peratures” on page 6).

• Control set too warm.

• Content temperature not stabi-

lized.

• Excessive usage or prolonged

door openings.

• Airflow to front grille blocked.

• Door gasket not sealing properly.

• Adjust temperature colder. Al-

low 24 hours for temperature to

stabilize.

• Allow temperature to stabilize for

at least 24 hours, with minimal

door openings.

• Airflow must not be obstructed to

front grille. See “clearances” on

page 4.

• Check door alignment and/or ad-

just or replace door gasket.

Unit too cold.

Adjust temperatures (See “Set Tem-

peratures” on page 6).

• Control set too cold.

• Door gasket not sealing properly.

• Adjust temperature warmer. (See

page 6, “set temperature”). Al-

low 24 hours for temperature to

stabilize.

• Check door alignment and/or ad-

just or replace door gasket.

No interior light.

• Failed light bulb.

• Replace light bulb, see page 14.

Light will not go out when door is

closed.

• Door not activating light switch.

• Verify cabinet is level, refer to

page 4 for leveling instructions.

• Verify the door is aligned properly,

refer to page 10 for instructions.

Noise or Vibration.

• Unit not level.

• Level unit, see “Leveling Legs” on

page 4.

Unit will not run.

• Unit turned off.

• Power cord not plugged in.

• No power at outlet.

• Turn unit on. See “Start your Appli-

ance” on page 6.

• Plug in power cord.

• Check house circuit.

Before You Call for Service

If the unit appears to be malfunctioning, read through this

manual first. If the problem persists, check the trouble-

shooting guide below. Locate the problem in the guide and

refer to the cause and its remedy before calling for service.

The problem may be something very simple that can be

solved without a service call. However, it may be required

to contact your dealer or a qualified service technician.

Electrocution Hazard

Never attempt to repair or perform maintenance on

the unit until the main electrical power has been

disconnected. Turning the unit control "OFF" does

not remove electrical power from the units wiring.