Install the Lower and Upper Vents

1. Using the following chart, decide which vents and rough opening (RO) sizes to use:

Certified Vent

P/N

RO Height

RO Width

Upper Roof Exhaust Cap

622293

N/A

N/A

Upper Roof Exhaust Vent

616319

24 in.

5 1/4 in.

Lower Metal Intake

616010

13 5/8 in.

21 5/8 in.

Upper Exhaust & Lower Intake Plastic

621156

13 3/4 in.

21 1/2 in.

2. Install the lower intake vent (See Art01598, Art01599, and Art01602):

The lower intake vent is also the service access opening for the components

on the rear of the refrigerator.

Make sure the bottom of the opening of the lower intake vent is

even with or immediately below the floor level. This allows any

leaking propane gas to escape to the outside and not to collect at

floor level.

- Make sure the bottom of the opening of the lower intake vent [9] is even with or

immediately below the floor level.

- Align the lower intake vent vertically below the coils [10] and the condenser [11] of the

refrigerator.

4. If there is more than 1/2 inch between either side of the refrigerator and the inside of the enclosure:

- Fill the space with fiberglass insulation or add a baffle to eliminate the excess clearance.

- Make sure that the rear of the batt-type insulation is between 18 - 19 inches from the face of the enclosure.

- Securely attach the batt-type insulation to the enclosure so that it remains in this position during refrigerator installation, if it

becomes wet, and in windy conditions.