MOUNTING INSTRUCTIONS
Reminder:
To prevent personal injury, disconnect one of the main battery
leads prior to installing the blower.

1.

Select a flat mounting surface high above the bilge, on the
transom or under the deck. Blower should be mounted high
and dry, clear of moisture from spray or deck wash.

2.

Position blower with fan nose cone pointing toward exhaust
vent. Also, mount blower at an angle to prevent moisture
build-up. See Figure 1

3.

Mark mounting holes using blower mounting feet as a tem-
plate. Drill holes for #10 screws.

4.

Secure unit in place using stainless steel screws.

Do not over

tighten screws, as this will crack the mounting feet.

5.

Twist duct hose over exhaust and intake openings on blower.
Ensure the retainer tabs engage corrugated rings of hose.

6.

Install tie strap or hose clamp on the hose. Position the strap or
clamp around blower housing, beyond the tabs. Tighten the
strap. When using a hose clamp, tighten until snug — 8 in/lb.
(.5N

.

m) max. Do not overtighten straps or clamps.

7.

Route intake end of hose directly to the lowest point in the
bilge, with as few bends as possible. The hose pick-up must
be below the top of the engine stringers, but not low enough
to become submerged in normal bilge water accumulation.
See Figure 1

8.

Route exhaust end of hose directly to vent or vent collector
box, with as few bends as possible. Connect hose securely
to vent. See Figure 1

Figure 1

Vertical
Transom Mount

Deck
Mount

Horizontal
Transom Mount

FEATURES

Turbo In-Line Bilge Blowers provide ventilation for engine compart-
ments, bilges, and marine head closets. Their unique fan blade is
computer-designed using the latest in aerospace technology.

The blowers’ compact in-line design allows for installation in
confined areas under the deck or on the transom; their built-in
mounting feet allow vertical or horizontal installation. Tabs on the
hose flanges grip the ventilation hose and prevent hose clamps
from sliding off after installation.

1745 model is a 24-Volt D.C., 4" (102mm) blower with a 1,000
hour rating. It is rated for 230 CFM (6.5 cubic meters/min.)
at open flow at 27.5-Volts. Current Draw = 2.5-Amps.

Blower model 1745 is water resistant. All Turbo Blowers
are ignition protected and meet ABYC and Coast Guard Safety
Standards.

Connect to 24-volt D.C. systems only.

WARNING:

To prevent personal injury, always disconnect electrical
connection when installing or servicing this product.

Always use a fuse with amperage rating specified for the
blower model. Failure to do so could result in serious personal
injury or fire hazards.

Before starting engines, operate blower a minimum of four
minutes, then check engine compartment for fume odor.

Do not operate in area of high heat over 160

°

F (71

°

C).

Do not operate while refueling.

REQUIRED FOR INSTALLATION

Drill and suitable drill bit

Screwdriver

Two #10 x 1/2" (13mm) stainless steel pan head screws

Corrugated vinyl duct hose, 4" (102mm) I.D. hose

Two tie straps or hose clamps for 4" (102mm) I.D. hose

Fuse—4-amp for 4" (102mm) blower,

Suitable in-line fuse holder

5-amp ON/OFF switch

16-gauge wire

Crimp-on wire connectors for 16-gauge wire

3

®

Attwood marine hardware, navigational lighting, bilge pumps, and other
marine accessories are specified more than any other brand by America’s
best-known boat manufacturers as original equipment. Look to Attwood
for quality replacement parts and marine accessories.

SAVE THESE INSTRUCTIONS

Form Number 69284 Rev. B

03-10

Turbo In-Line 24-Volt D.C.
Bilge Blowers