Tweco 7-3476 Manuel d'utilisation

Page 4

Advertising
background image

August 6, 2003 / 6 Août, 2003

4

Manual / Manuel 0-2958

B. Adapter Installation - for 'Type B' Applications

1. Pass the end of the leads or ATC Adapter through the torch leads opening in the Power Supply.

2. Inside the Power Supply, slide the Strain Relief securing nut onto the Leads or Adapter. Tighten the securing

nut onto the Strain Relief to secure the strain relief to the Power Supply.

3. Refer to the illustration. Slide the insulating sleeve provided in this kit onto the Torch Leads or ATC Adapter

Kit Negative / Plasma fitting (only). Do not enclose the wires.

4. Connect the negative / plasma connector fitting from this adapter kit to the ATC Adapter or Leads plasma

fitting. Do not use sealant. Tighten securely.

Negative/Plasma

Lead

Large Insulating Sleeve (Installed)

RPT Adapter Kit

ATC Adapter Kit

A-03714

Strain Relief

Securing Nut

Strain Relief

Assembly

Strain Relief

Dome Nut

Negative / Plasma

Connector Fitting

To Power Supply

Pilot Connection

To Power Supply

Control Circuitry

(All Applications)

Torch Leads

Assembly

Wires Connected

and Insulated

To Power Supply

Torch Connection

5. Slide the large insulating sleeve over the Torch Leads or ATC Adapter plasma fittings, and the negative /

plasma fitting. The sleeve must completely cover the fittings on both the Leads or ATC Adapter, and the
negative / plasma fitting.

8. Connect the pilot wire (+) on the ATC Adapter or Torch Leads wire to the pilot connector on the Power

Supply.

9. Connect the plasma line provided in this kit to the Power Supply plasma connector. Do not use sealant.

Tighten securely.

10. Connect the plasma line to the plasma connector on the RPT Adapter Kit negative / plasma fitting. Check for

a secure connection.