Tweco 7-3465 Manuel d'utilisation
Page 4
June1, 2004 / 1 Juin, 2004
4
Manual / Manuel 0-4646
5. Refer to the illustration. Install the flare fitting included in this kit on the smaller Power Supply connection fitting. Tighten
securely. Capture the pilot lead ring terminal (from the ATC Adapter Kit or Torch Leads) between the flare fitting and the
hex nut supplied in this kit. Tighten securely. Connect the small adapter fitting to the flare fitting. Tighten securely. Do
not use sealant.
6. Connect the connectors on the Control Wire Connectors to mating torch control wire connectors on the Torch Leads or
ATC Adapter Kit.
CAUTION
Refer to the illustration on the previous page for Control Wire Connections for Hand Torch or for ATC Adapter.
Refer to the illustration on this page for Control Wire Connections for SL100 Machine Torch with O2B Connec-
tions (including Remote Pendant Adapter).
7. Slide the Connection Cover along the ATC Adapter Leads or Torch Leads to position it against the Power
Supply front panel. Note that the flange on the bottom edge of the Connection Cover must fit inside the bottom
of the torch connection opening on the power supply. Ensure that all wires are inside the Connection Cover.
Attach the Connection Cover to the Power Supply with hardware provided in this kit.
Torch Leads
Assembly
Through-Hole Protector
Securing Nut
Through-Hole
Protector Dome Nut
Through-Hole
Protector Assembly
Torch Leads
Torch Adapter
Connection Cover
Torch Control
Terminals
Control Wire Connectors (2)
Art # A-04009
Mounting Hardware
Negative / Plasma
Connector
Large
Adapter
Fitting
Insulating
Sleeve
Pilot Lead
Hex Nut
Small Gas Connector
Torch
Control
Wires
Torch Connection Opening
in Power Supply Front Panel
Ring Terminal
Small
Adapter Fitting
Negative/Plasma
Lead Fitting
Tie Wrap
Bottom Flange
Flare Fitting
Open
Open
Remote
Pendant Adapter
Start Signal from
Remote Pendant
Connections for Machine Torch Leads with O2B Connector and Remote Pendant Adapter