Rockwell Automation 1769-ADN DeviceNet Modules Installation Instructions Manuel d'utilisation

Page 56

Advertising
background image

56

Rockwell Automation Publication DNET-IN001B-EN-P - January 2012

Appendix B 1769 DeviceNet Modules Status Indicators and Data Structures

Table 8 - Module Status Indicator

Status

Description

Off

The adapter is not powered.
Verify that the adapter is installed correctly.

Flashing green

The adapter is online, but the configuration is missing.
Configure the adapter.

Solid green

The adapter is fully operational and is communicating with other
devices on the network.
No action is required.

Flashing red

The adapter has experienced a recoverable fault due to one of these
conditions:

Configuration is incorrect.

Duplicate MAC ID check has failed.

Node address switch has changed.

Main program checksum has failed.

Configured I/O size is too large.

Solid red

The adapter has experienced an unrecoverable fault due to one of
these conditions:

Terminator/end cap is missing.

Connector or cable between devices is missing or no longer

connected.

An issue with the configuration memory exists.

Watchdog has been tripped.

Table 9 - I/O Status (IO) Indicator

Status

Description

Off

The adapter is not powered.
Verify that the adapter is installed correctly.

Flashing green

The adapter is in Idle mode, outputs are not under control, and inputs
are being consumed.
To control output devices, place the adapter in Run mode.

Solid green

The adapter is in Run mode, outputs are under control, and inputs
are being consumed.
No action is required.

Flashing red

The adapter has experienced a recoverable fault because one or
more of the I/O modules may be in Fault mode.
Check the I/O modules to determine which ones are in Fault mode
and remedy that issue.

Solid red

The adapter has experienced an unrecoverable fault because one or
more of the I/O modules may be in Fault mode.
Check the I/O modules to determine which ones are in Fault mode
and remedy that issue. If you remedy the issue and the status
indicator remains solid red, replace the adapter.

Advertising