Installing lp gas tank, Installing natural gas line, Operating instructions – Blue Rhino LP GAS BARBECUE GRILL GBC1076WE-C Manuel d'utilisation

Page 11

Advertising
background image

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

page no.

11

Installing LP Gas Tank

To operate you will need (1) precision-filled standard grill LP gas
tank (20#) with external valve threads.
Note: An empty standard grill LP gas tank weighs approximately
18 lbs. A precision-filled standard grill LP gas tank should weigh
no more than 38 lbs.

Caution: LP gas tank must be properly

disconnected and removed prior to moving this

grill.

Insert LP Gas Tank

Place precision filled LP gas tank upright into hole in tnk tray so the tank valve is facing the gas
line connection.

Secure LP Gas Tank

Secure tank by sliding tank retainer wire over shoulder of LP gas tank.

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in
the head of the LP gas tank, head of the regulator valve or
in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it
stops.

Disconnect LP Gas Tank

Before disconnecting make sure the LP gas tank valve is
“CLOSED”.
Disconnect gas line from LP gas tank by turning knob
counterclockwise until it is loose.

Caution: LP gas tank must be properly

disconnected and removed prior to moving

this grill.

Need a tank of gas? Try tank exchange service. It’s easy, fast, safe,
and available at tens of thousands of conveniently located retail outlets
nationwide. You can purchase a new full tank or exchange your empty for
a precision filled one.

Installing Natural Gas Line

Installation should be done by a qualified service
person.

CAUTION: If young children are in

the area, a locking valve should be
considered.

Connect Natural Gas Line

Before connecting, be sure that there is no debris
caught in the head of the natural gas line, head of the
grill natural gas line or in the head of the burner and
burner ports.
Connect grill natural gas line to natural gas line.

Disconnect Natural Gas Line

Before disconnecting make sure the natural gas line
valve is “OFF”.
Disconnect grill natural gas line from natural gas line.

Operating Instructions

Checking for Leaks

Burner Connections

1. Make sure the regulator valve and hose connections

are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.

WARNING: Failure to inspect this

connection or follow these instructions

could cause a fire or an explosion

which can cause death, serious bodily

injury, or damage to property.

2. Please refer to diagram for proper installation.

(Figures 2 and 3)

3. If the burner pipe does not rest flush to the orifice,

please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

1. Make 2-3 oz. of leak solution by mixing one part

liquid dishwashing soap with three parts water.

2. Make sure control knobs are (OFF) position.

(Figure 4)

3.

LP: Turn LP gas tank valve to “OPEN”.
NG: Turn “ON” natural gas main valve.

4. Spoon leak check solution at all “X” locations

(Figures 2, 3, 5a and 5b)
a.

LP: If any bubbles appear turn LP gas tank valve
to “CLOSED”, reconnect and re-test.
NG: If any bubbles appear turn natural gas main
valve “OFF”, reconnect and re-test.

b.

LP: If you continue to see bubbles after several
attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank and contact
1.800.762.1142 for assistance.
NG: If you continue to see bubbles after several
attempts, turn natural gas main valve “OFF”
and disconnect natural gas line and contact
1.800.762.1142 for assistance.

c.

LP: If no bubbles appear after one minute turn LP
gas tank valve to “CLOSED”, wipe away solution
and proceed.
NG: If no bubbles appear after one minute turn
natural gas main valve “OFF”, wipe away solution
and proceed.

Figure 1

Figure 2

XX

XX

Burner
venturi
pipe

Back Burner Soft Pipe
Connection

LP Gas
Valve with
Orifice

Main Burners

Valve
Soft Pipe
Connection

Figure 3

XX

XX

LP Gas
Connection

LP Gas Valve
with Orifice

Valve
Soft Pipe
Connection

Side Burner

Burner
venturi
pipe

Figure 4

Figure 5a

X

X

X

X

X

Figure 5b

X

X

Advertising