EDK82MV752-BB DE/EN/FR 1.0

Adjustment
1. Calculate C0120. This value corresponds to a motor utilisation of 100 %:

C0120 [%] =

I

r

I

N

⋅ 100 %

I

r

Rated motor current

I

r

Rated controller current at switching frequency 8 kHz

2. If you decrease C0120 on the basis of the value calculated, the monitoring already

responds at a motor utilisation < 100 %.

3. If you increase C0120 on the basis of the value calculated, the monitoring only

responds at a motor utilisation > 100 %.

The controller switches off with error OC6 if the apparent motorcurrent is greater thanthe

rated motor current for a longer time.

60

180

240

300

360

t [s]

0.5

0

0

1.0

1.5

2.0

C0054

I

r

120

f = 0 Hz

f = 20 Hz

f > 40 Hz

I x 100 %

I

r

N

C0120 <

I x 100 %

I

r

N

C0120 =

I x 100 %

I

r

N

C0120 >

8200vec523

f

Output frequency

t

Release time

I

N

Rated controller current at switching frequency 8 kHz

I

r

Rated motor current

C0054

Apparent motor current

Example:

`MNOM =

f

ê

f

k

⋅ NMM B

C0054 = 1.5 x rated motor current
The controller switches off at output frequencies f > 40 Hz with error OC6 after

approx. 60 s.