1. Ensure pilot flame is lit and adjusted.

2. Turn oven temperature control to 200°F, (93°C), and allow

the oven to heat for three minutes.

3. Turn, the oven temperature control to the lowest

position, then turn slowly counter-clockwise until the
audible “click” is heard.

4. Making sure the oven temperature control dial is not

disturbed, turn the by-pass flame adjusting screw
clockwise to decrease, or counter-clockwise to increase
the flame on the burner to the lowest possible stable
flame. When properly adjusted, the by-pass flames will
cover the entire length of the burner.

Calibration Instructions

Field calibration is seldom necessary and should not
be resorted to unless experience with cooking results
undoubtedly indicate that the control is not maintaining
the temperature for which the dial is set. To check oven
temperatures when calibrating, use only a reliable mercury
thermometer, or preferably an oven pyrometer. To check
calibration, proceed as follows:

1. Place the thermocouple of the test instrument or reliable

mercury thermometer in the center of the oven.

2. Turn the oven temperature control knob to 400°F, (204°C),

and allow the oven to cycle at least three times.

3. Continue to monitor the oven temperature, recording

the readings at 5 minute intervals until three successive
readings are within 5°F, (2°C), of each other.

If the temperature does not read within 15°F, (8°C), of the dial
setting, recalibrate as follows.

1. Remove the oven temperature control dial, making sure

the setting is not disturbed.

2. Hold the calibration plate, (located directly behind the

control dial), and loosen the two calibration lock screws
until the plate can be rotated independently of the
control.

3. Turn the calibration plate until the temperature indicated

on the plate corresponds with the reading on the test
instrument. Hold the plate in place and tighten the
screws firmly.

4. Repeat step 3 in the previous section, checking the

temperature to ensure the adjustment has been made
properly.

5. Replace the temperature control dial.

NOTE: If adjustment of the calibration plate is prevented by
the position of the lock screws, the screws can be moved to
other holes that have been tapped for them.