Outdoor Patio Heater Model No. GWU9209SP & GWU9209W

Troubleshooting

Problem

Possible Cause

Prevention/Cure

Pilot won’t light

Igniter fails

Light the heater manually with a match, per the “Lighting
Instructions”. If heater lights with a match, replace igniter

Pilot or orifice

Clean the pilot assembly: Download and follow the correct
cleaning instructions from www.bluerhino.com

LP gas tank valve is closed

Make sure regulator is securely attached to the LP gas tank,
turn LP gas tank valve to “OPEN”

Air in gas line

1. Open gas line and bleed it (pressing control knob in) for not

more than 1 - 2 minutes or until you smell gas

2. Turn control knob to “OFF”
3. Wait at least 5 minutes for gas to dissipate

Low gas pressure with tank valve fully “OPEN”

Turn LP gas tank valve “CLOSED” and replace LP gas tank

Pilot won’t stay lit
(Residential/Commerical Heaters Only)

Note: Heater operates at reduced efficiency below
40ºF (5ºC).

Dirt built up around pilot

Clean the pilot assembly: Download and follow the correct
cleaning instructions from www.bluerhino.com

Connection between gas valve and pilot assembly is loose

Tighten connection and perform leak check

Air in gas line

Open gas line and bleed it (pressing control knob in) for not
more than 1 - 2 minutes or until you smell gas

Thermocouple is not operating correctly

Clean the heater: Download and follow the correct cleaning
instructions from www.bluerhino.com

Burner won’t light

Note: Heater operates at reduced efficiency below
40ºF (5ºC).

Control knob is not in “ON” position

Review “Lighting Instructions” and try again

LP gas pressure is low

Turn LP gas tank valve “CLOSED” and replace LP gas tank

Blockage in orifice

Clear blockage: Download and follow the correct cleaning
instructions from www.bluerhino.com

Connection between gas valve and burner assembly is loose Tighten connection and perform leak check
Air in gas line

Open gas line and bleed it (pressing control knob in) for not
more than 1 - 2 minutes or until you smell gas

Burner won’t stay lit

Connection between gas valve and burner assembly is loose Tighten connection and perform leak check
Thermocouple is not operating correctly

Clean heater if still not working, obtain a new thermocouple
from the manufacturer

Burner flame is low

Note: Heater operates at reduced efficiency below
40ºF (5ºC).

LP gas pressure is low

Turn LP gas tank valve “CLOSED” and replace LP gas tank

Outdoor temperature is less than 40ºF and tank is less than
1/4 full

Use a full LP gas tank

Supply hose is bent or kinked

Straighten hose, if cracked obtain a new hose from the
manufacturer

Emitter glows uneven

Note: Bottom 1” of emitter normally does NOT
glow.

LP gas pressure is low

Turn LP gas tank valve “CLOSED” and replace LP gas tank

Base is not on a level surface

Place heater on a level surface

Blockage in burner

Clean the burner: Download and follow the correct cleaning
instructions from www.bluerhino.com

Thick black smoke

Blockage in burner

Remove blockage and clean burner inside and outside:
Download and follow the correct cleaning instructions from
www.bluerhino.com