6.5 O “Diagnose” Menu

DIAGNOSE

00001

Pendant on/off button
Pendant advance button

(not used
on this
pump version)

Screen 15

PSI MPa

BAR Nm

Ft-lb

(See Screen 15) This screen allows
the operator to troubleshoot various
pendant problems. If the number “1”
does not appear when a pendant
button is pushed, problems with
the pendant button switches and/or
pendant cord may be present (See
Screens 16 and 17). Use Local mode
to operate pump until the problem can
be corrected. Refer to QRC step #11.

Press

Screen 16

DIAGNOSE

01001

PSI MPa
BAR Nm
Ft-lb

Diagnose screen
with pendant
on/off button
pushed.

Press

Screen 17

DIAGNOSE

10001

PSI MPa
BAR Nm
Ft-lb

Diagnose screen
with pendant
advance button
pushed.

6.5 P “Calibration” Menu

CAL PT A

0

SET

Screen 18

PSI

(See Screen 18) This screen allows the
operator to adjust the pressure value
shown on the LCD to match a master
gauge.

To access the Calibration menu, fi rst
go to the Units menu.

Then, press and hold the shroud Motor
on/off button for 7 seconds. ENTRY CODE will appear on the
LCD.

Then, press and hold both the Down Arrow and Up Arrow buttons
for 7 seconds. CAL PT A will appear on the LCD.

See Table 2, “Z-Class Pressure Transducer Calibration”, located
near the end of this document. Follow the steps in the table to
perform calibration procedures.

6.6 LCD Fault Conditions

Any fault condition will shut down the pump and prevent it from
starting.

6.6 A Clearing a Fault Condition from the LCD

After the fault causing problem has been corrected, clear the fault
message from the LCD by disconnecting electrical power from
the pump. Wait until all characters clear the LCD (~ 20 seconds),
then reconnect power.

6.6 B Power Off Fault

Display: “POWER OFF”

POWER

OFF

Screen 19

See Screen 19) The Power Off fault
occurs when the AC line power drops
to 65% or less of nominal voltage. The
pump will automatically shut-off the
valve solenoid and motor, and “Power
Off” will be displayed on the LCD.
Note: The Power Off message will also
appear for several seconds after the
pump has been disconnected from
electrical power.

6.6 C Button Fault

Display: “BUTTON FAULT”

BUTTON

FAULT

Screen 20

(See Screen 20) The Button fault occurs
when the microcontroller detects that
any button has been pressed during
the boot sequence or if the shroud
Motor on/off button has been pressed
for more than 3 seconds.

6.6 D Motor Overload Fault

Display: “MTR OVLD FAULT”

and “Motor Overload”

MTR OVLD

FAULT

Screen 21

MOTOR
OVERLOAD

(See Screen 21) The Motor Overload
fault occurs when the electrical current
draw exceeds the pre-set limit of
the pump’s internal circuit breaker.
The circuit breaker will automatically
reset in about 2 to 3 minutes after
the condition has been corrected.
However, before the pump can be
restarted, the operator must clear the fault by disconnecting
and reconnecting electrical power as described in Section 6.6 A.

6.6 E Oil Temperature Fault

Display: “OIL TEMP FAULT”

OIL TEMP

FAULT

Screen 22

Note: The LCD will display this fault only if the pump is equipped
with the optional oil / level temperature switch (available only on
2.5, 5, and 10 gallon reservoir sizes).

(See Screen 22) The Oil Temperature
fault occurs when the temperature
of the oil inside the reservoir exceeds
175 ºF [80 °C].

9