Enerpac ZU4T-Series Manuel d'utilisation

Page 14

Advertising
background image

14

T

a

ble 2 , Z-Class Pr

essur

e T

ransducer Calibration, Firmwar

e 7.x

T

o

rque W

rench Pumps Equipped with Single Solenoid V

alve

Comments

Boot sequence.

psi is the current unit of pressure measurement.

Step into the hidden calibra

tion mode.

Start of calibra

tion process.

The advance-solenoid will be po

wered up to access the pressure transducer

through valve-port

A.

Calibra

te the zero-offset,

point

“A

”.

Confi

rm the pressure da

ta should be stored to memor

y.

Calibra

ting gain is done with two points,

starting with point

“B”.

First obtain the pressure value on the master gauge (ie 5000 psi).

Then use the arro

w buttons to ma

tch the

LCD value to the master gauge.

Confi

rm the pressure da

ta should be stored to memor

y.

Calibra

ting gain is done with two points,

fi

nishing with point

“C”.

First obtain the pressure value on the master gauge (ie 8000 psi).

Then use the arro

w buttons to ma

tch the

LCD value to the master gauge.

Confi

rm the pressure da

ta should be stored to memor

y.

Re-confi

rm calibra

tion da

ta.

Lea

ve

“off

” to proceed with new calibra

tion da

ta.

Only set to

“on”

to change

calibra

tion da

ta back to factor

y default settings.

Press

Arro

w button to change.

Sa

ve calibra

tion da

ta to permanent memor

y.

Calibra

tion complete.

Motor stops and electric valve releases pressure.

LCD

Reading

0 psi

psi

CODE

O psi

[O bar]

O psi

[O bar]

no

yes

5000 psi

[345 bar]

5000 psi

[345 bar]

no

yes

8000 psi

[548 bar]

8000 psi

[548 bar]

no

yes

off

O psi

[O bar]

O psi

[O bar]

FIRMW

ARE 7.x,

then “READ

Y”

UNITS

ENTR

Y

CAL PT

A

CAL PT

A

SA

VE A

SA

VE A

CAL PT B

CAL PT B

SA

VE B

SA

VE B

CAL PT C

CAL PT C

SA

VE C

SA

VE C

USE DFL

T

CAL PT

A

READ

Y

Operator

action

Connect a master gauge to port

A (Advance port)

Connect electrical po

wer to pump.

At main screen,

press the Menu button once to display

“UNITS”

screen.

Press and hold the ON/OFF button for seven seconds.

Press and hold the

Arro

w-up and

Arro

w-do

wn buttons together for seven seconds.

Open the pump’

s user

-adjustable relief valve and verify both pump LCD and master

gauge read zero.

Press the Menu button to accept the pressure value into temporar

y memor

y.

Press one

Arro

w button to change from

“no”

to

“yes”.

Press the Menu button once.

Press and release the shroud’

s ON/OFF motor

-button to s

witch the pump motor on.

Reading the master gauge,

a

p

ply a pressure of 5000 psi by c

losing the pump’

s user

-

adjustable relief valve.

Press the Menu button to accept the pressure value into temporar

y memor

y.

Press one

Arro

w button to change from

“no”

to

“yes”.

Press the Menu button once.

Reading the master gauge,

a

pply a pressure of 8000 psi.

Press the Menu button to accept the pressure value into temporar

y memor

y.

Press one

Arro

w button to change from

“no”

to

“yes”.

Press the Menu button once.

Press the Menu button once.

Press and hold the Menu button for three seconds to step out of the calibra

tion mode.

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19