Carter-Hoffmann CGM24 Manuel d'utilisation

Page 4

Advertising
background image

4

Electrical Specifications

MODEL

WATTS

VOLTS

AMPS

NEMA

CGM24

2280 208

10.96

6-20P

CGM24-240

2280 240 9.5

6-20P

INSTALLATION AND START-UP

LOCATION

For proper operation and maximum performance, locate the unit in an ambi-
ent air temperature of 70ºF (21ºC). Avoid placement in areas near exhaust
fans or where there are active air movements.

For safe operation and maximum performance, locate the unit at least 2”
from any wall or combustible material to allow for adequate cooling.

To prevent injury and damage, locate the unit at a proper and safe working
height and a reasonable distance from combustible walls and materials.
The location should be level, clean of debris, and strong enough to support
the weight of a fully loaded unit.

GROUNDING INSTRUCTIONS

This appliance is equipped with a cord having a grounding wire with a
grounding plug which must be plugged into an outlet that is properly in-
stalled and grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric
current.

WARNING—Improper use of the grounding can result in a risk of elec-
tric shock.
Consult a qualified electrician or service agent if the grounding
instructions are not completely understood, or if doubt exists as to whether
the appliance is properly grounded.

If necessary, contact a licensed
electrician to install an appropriate
20 amp electrical circuit with correct
NEMA 6-20R receptacle.

DO NOT use an extension cord.

Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes. Failure could
result in personal injury and proper-
ty damage.

Damage to unit due to being
connected to the wrong voltage or
phase is NOT covered by warranty.

START UP

1. Prior to use, thoroughly clean the unit, per the instructions in this manu-

al on page 6. Familiarize yourself with the controls.

2. Check for proper voltage & circuit breaker size. Cabinet requires 208 or

240 volt (depending on model), single phase, 20 Amp circuit.


3. Ensure receptacle is correctly installed and operating safely. Requires

properly grounded NEMA 6-20R receptacle.


4. Plug the power cord of the cabinet into a grounded outlet with

a electrical service according to the electrical information pro

vided below. DO NOT MODIFY CORD OR PLUG.


5. Set POWER switch to the “ON” position.

6. Do not load product into the cabinet. Allow the heat to remove

any residual oils which may adhere to inside metal surfaces. A slight

emission of smoke is common during the first few minutes of operation.

T

he ground prong of the power

cord is part of a system designed to
protect you from electric shock in
the event of internal damage.

DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.

CAUTION:

Electrical Shock Hazard

Unit is not waterproof, to avoid
electrical shock, keep unit from be-
ing submerged in water. Do not
operate if unit has been in contact
with water.

IMPORTANT:

Power cord is 6' long

IMPORTANT:

Not under warranty

WARNING:

Risk of personal injury

WARNING:

Risk of personal injury

To prevent an electrical shock hazard between the appliance
and other appliances or metal parts in close vicinity, an equali-
zation-bonding stud is provided. An equalization bonding lead
must be connected to this stud and the other appliances/metal
parts to provide sufficient protection against potential differ-
ence. The terminal is marked with the following symbol:

Advertising