Gas supply requirements, Gas supply line, Dryer gas connection – Whirlpool WGT3300XQ Manuel d'utilisation

Page 10: Gas supply connection requirements, Burner input requirements

Advertising
background image

10

A. 3/8" flexible gas connector

B. 3/8" pipe to flare adapter fitting

C. 1/8" NPT minimum plugged tapping

D. 1/2" NPT gas supply line

E. Gas shut-off valve.

GAS SUPPLY LINE

n

Must include 1/8" NPT minimum plugged tapping accessible

for test gauge connection, immediately upstream of the gas

connection to the washer/dryer. See illustration below.

n

1/2" IPS pipe is recommended.

n

Must include shut-off valve:

In the U.S.A.:

An individual manual shut-off valve must be installed within

six (6) ft. (1.8 m) of the washer/dryer in accordance with the

National Fuel Gas Code, ANSI Z223.1. The location should

be easy to reach for opening and closing.

In Canada:

An individual manual shut-off valve must be installed in

accordance with the B149.1, Natural Gas and Propane

Installation Code. It is recommended that an individual

manual shut-off valve be installed within six (6) ft. (1.8 m)

of the washer/dryer. The location should be easy to reach

for opening and closing.

This washer/dryer is equipped with its own permanent,

flexible gas connector, design-certified by CSA International,

for connecting the washer/dryer to the gas supply line.

A

B

E

D

C

Flexible gas connector

†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.

DRYER GAS CONNECTION

Option 1

Rigid gas supply line:

n

Connect your washer/dryer to the rigid gas supply line using

an elbow and a 3/8" flare x 3/8" NPT adapter fitting between

the stainless steel gas connector and the washer/dryer gas

pipe, as needed to prevent kinking.

Option 2

Approved aluminum or copper tubing:

n

3/8" approved aluminum or copper tubing is acceptable for

lengths under 20 ft. (6.1 m) if local codes and gas supplier

permit.

n

If you are using natural gas, do not use copper tubing.

n

Lengths over 20 ft. (6.1 m) should use larger tubing and

a different size adapter fitting.

n

If your washer/dryer has been converted to use LP gas, 3/8"

LP compatible copper tubing can be used. If the total length

of the supply line is more than 20 ft. (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas

must be used. Do not use TEFLON

®†

tape.

GAS SUPPLY CONNECTION REQUIREMENTS

n

Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting

between the flexible gas connector and the washer/dryer gas

pipe, as needed, to avoid kinking.

n

Use only pipe-joint compound. Do not use TEFLON

®†

tape.

BURNER INPUT REQUIREMENTS

Elevations up to 10,000 ft (3,048 meters):

n

The design of this washer/dryer is certified by CSA

International for use at altitudes up to 10,000 ft (3,048 m)

above sea level at the Btu rating indicated on the model/serial

number plate. Burner input adjustments are not required when

the washer/dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 meters):

n

When installed above 10,000 ft. (3,048 m) a 4% reduction of

the burner Btu rating shown on the model/serial number plate

is required for each 1,000 ft. (305 m) increase in elevation.

Gas supply pressure testing

n

The washer/dryer must be disconnected from the gas supply

piping system during pressure testing at pressures greater

than 1/2 psi.

GAS SUPPLY REQUIREMENTS