Make Electrical Connection

1. Disconnect power.

2. Remove terminal box cover.

3. Remove the knockout in the terminal box and install a UL

listed or CSA approved

¹⁄₂" strain relief.

4. Run home power supply cable through strain relief, into

terminal box.

5. Use UL listed wire connectors and connect black wires (C)

together.

6. Use UL listed wire connectors and connect white wires (E)

together.

7. Connect green (or bare) ground wire from home power supply

to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.

8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.

Optional Power Cord Kit Installations

For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or Service”
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.

Install Vent Covers

When using both upper and lower vent covers, push lower cover
down onto hood and lift upper cover to ceiling and install with
2 - 4.2 x 8 mm screws.

NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.

A. Knockout
B. Terminal box

C. Terminal box cover

A. Home power supply cable
B. UL listed or CSA approved

strain relief

C. Black wires

D. UL listed wire connectors

E. White wires

F. Green (or bare) and yellow-

green ground wires

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

C

B

A

B

C

D

E

F

A. Bracket
B. 4.2 x 8 mm screws

C. Vent cover

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire
in terminal box.

Failure to do so can result in death or electrical shock.

C

A

B

Advertising